![Midea MGS30S2AST Installation Instructions Manual Download Page 25](http://html1.mh-extra.com/html/midea/mgs30s2ast/mgs30s2ast_installation-instructions-manual_1791485025.webp)
25
High Altitude Conversion (optional):
• Reduced air pressure and oxygen availability at high altitudes may
affect proper burner combustion. Failure to properly convert the
range for high altitude installations can result in increased risk carbon
monoxide. The conversion must be performed by a qualified service
technician in accordance with the manufacturer's instructions and all
local codes and requirements. The agency performing this work
assumes responsibility for the conversion.
Units must be converted for proper operation at elevations in excess of
6,000 feet. Conversion kits will be provided free-of-charge by
contacting Midea customer service at
āġĉććġćąćġąăăĂ
or by visiting
High altitude conversion requires all cooktop and oven burner orifices
to be changed. Follow detailed instructions included with the conversion
kit. The regulator must be set according to the fuel type in use at the
installation site. (See "Convert to LP Gas" for information on fuel type
settings.) Save the orifices removed from the appliance for future use.
All replaced orifices must be left with the consumer, along with the
conversion instructions.
IMPORTANT
SAFETY
INSTRUCTIONS
BEFORE
STARTING
INSTALLATION
INSTALLATION
PROCEDURE
CONFIRM
OPERATION
TROUBLESHOOTING
SAFETY
DEFINITIONS
:$51,1*
ŏ ŏ
)% !ċ+)ĥ1/ĥ/1,,+.0
.