9.3.5 High pressure protection
9.3.6 Low temperature protection
9.3.7 Low pressure protection
Low temperature protection
Possible reason
1: The outdoor ambient temp. is low.
2: The wires are loose to the temp. sensor.
3: The temp. sensor is defective.
4: The evaporator or the filter is dirty.
5: System has block.
Low pressure protection
Possible reason
1: The wires are loose to the pressure switch.
2: The pressure switch is defective.
3: System has refrigerant leakage.
4: The evaporator or the filter is dirty.
5: System has block.