background image

CD046IU-DG(ZG)N7

16120100000376

Before operating this product, please read the instructions
carefully and save this manual for future use.

DEHUMIDIFIER

The design and specifications are subject to change without prior notice for 
product improvement. Consult with the sales agency or manufacturer for details.
Any updates to the manual will be uploaded to the service website, please check
for the latest version.

GD MIDEA AIR-CONDITIONING EQUIPMENT CO.,LTD.
Lingang Road  Beijiao  Shunde  Foshan  Guangdong  People s Republic of China  528311

MDDG-20DEN7-QA3 

R290/0.09kg

MODEL:

REFRIGERANT:

Summary of Contents for MDDG-20DEN7-QA3

Page 1: ...ject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for...

Page 2: ...ter and find their way into the food chain When using this dehumidifier in the European countries the following information must be followed 1 CONTENTS SAFETY PRECAUTIONS Warning 2 Caution 2 Electrica...

Page 3: ...other foreign objects into grills or openings Take special care to warn children of these dangers Do not use in areas where chemicals are handled This will cause the unit deterioration due to chemical...

Page 4: ...r specific information on the type the amount and the CO2 equivalent in tonnes of the fluorinated greenhouse gas on some models please refer to the relevant label on the unit itself Installation servi...

Page 5: ...ted This shall include damage to cables excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that apparatus is mounted se...

Page 6: ...mum working pressure of the cylinder even temporarily j When the cylinders have been filled correctly and the process completed make sure that the cylinders and preventing the ingress of flammable atm...

Page 7: ...n that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppliers Only electric heating to the compressor...

Page 8: ...displays the code of P2 the Auto Start Stop function will also be cancelled Auto Shut Off The dehumidifier shuts off when the bucket is full or when the bucket is removed or not replaced in the prope...

Page 9: ...ig 7 NOTE When the continuous drain feature is not being used remove the drain hose from the outlet and reinstall the rubber plug Attach the hose to the drain hose outlet Remove the rubber plug Water...

Page 10: ...ore often if necessary NOTE DO NOT RINSE OR PUT THE FILTER IN AN AUTOMATIC DISHWASHER To remove Grip the tab on the filter and pull it upward then pull it out as shown in Fig 8 Clean the filter with w...

Page 11: ...humidity control may not be set low enough Check that all doors windows and other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something gi...

Reviews: