Before repairing, use multimeter to judge circuit stand of fail
.
41
No
Part
Picture
Test Description
parameters
5
Water
Level
Sensor
Conducting both ends with a
multimeter test case, disconnect the
float at the bottom of the float.
10mv-24vAC;10mv-
200vDC ,10VA 10W,
10UA-1A(DC)
6
Door
Switch
Conducting both ends with a
multimeter test case, under normal
disconnect, press on.
250V 16A
7
Motor
Assembly
220-240V,
50/60Hz,150W,
Copper wire, Class
155
8
Cooling
fan
AC 220~240V~50/60Hz, 0.07/0.07A
220-240VAC,
50/60Hz
6 Check Point of Electronic Components