background image

6

  Common Display Data: 

1.Figure 

 means CCM is sending 

query order;
2.Figure   means CCM is in 
communication connection with PC, 
and it will be off in 20 seconds with no 
communication;
3.Figuer   means CCM is in 
communication connection with outdoor 
unit, and it will be off in 20 seconds with 

communication
4.Press the OK button in setting page 
and waiting for 4 seconds,"success"or 
"fail" will be shown in the operation state 
area.;

  Stand-by Page Display:

1.Figure 

 means the total number 

of online modules;
2.Figure 

 means the total number 

of online outdoor units;

4-2-2 Datas

Graph 2 LCD Screen

OR display 

'

 

with the model: MD-CCM02/E(H)

Summary of Contents for MD-CCM02/E

Page 1: ...1 OWNER S MANUAL CENTRAL MONITOR CONTROL MD CCM02 E Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference...

Page 2: ...cautions that should be brought to your attention during operation In order to ensure correct service of the wired controller please read this manual carefully before using the unit For convenience of...

Page 3: ...3 CONTENTS 1 SAFETY PRECAUTION 1 2 SUMMARIZE OF OUTDOOR CCM 2 3 BASIC REQUIREMENTS 3 4 OPERATION 3 5 INSTALLATION 10 6 TECHNICAL INDEX AND REQUIREMENT 11...

Page 4: ...on Identifier Meaning Warning Means improper handling may lead to personal or severe injury Caution Means improper handling may lead to personal injury or property loss Note 1 Harm means injury burn a...

Page 5: ...only can be realized when the system is in normal operation 1 Central Control Monitor can realize the central control and data query to outdoor units One outdoor CCM can connect max 8 refrigerant sys...

Page 6: ...e off 2 second later the system enters into normal display state the CCM is in the main page and display the data in the first page Network Area Address Setting The PC or gateway can connect max 16 se...

Page 7: ...BUTTON Push it to enter into the query state 2 PREVIOUS BUTTON On the query state push it to query in default the running states of other online air conditioners 3 NEXT BUTTON On the query state push...

Page 8: ...to enter into Set Page 7 MODE BUTTON Pressing MODE button to enter into MODE set and select circularly between Forced Cooling and OFF state 8 OK BUTTON Pressing OK button to confirm all settings and...

Page 9: ...ication connection with outdoor unit and it will be off in 20 seconds with communication 4 Press the OK button in setting page and waiting for 4 seconds success or fail will be shown in the operation...

Page 10: ...ate Display COMP 1 2 3 4 6 Electromagnetism Valve Display EMV 1 2 3 4 5 6 7 4 Ways Valve Display 8 Defrost Display Defrost 9 Oil Return Display OIL RETURN 10 Page0 displays the consumption of electric...

Page 11: ...Page14 displays the openness of electromagnetism valve symboled 2 with VALVE OPENNESS 2 and the number 25 Page15 displays the most advanced malfunction with MALFUNCTION and the code 26 Page16 displays...

Page 12: ...on valid for host unit P8 Compressor Current 3rd Protection H1 Net communication malfunction P7 Compressor Current 2nd Protection EF Other malfunction P5 Condenser High Temp Protection E4T4 Temp Senso...

Page 13: ...e concave on bottom panel of the Wire Controller to remove the Back Cover When installing the Wire Controller you should adjust the bottom of the Wire Controller Board to the Wire Controller Back Cove...

Page 14: ...11 6 TECHNICAL INDEX AND REQUIREMENT EMC and EMI should conform to the requirement of CE Certification...

Page 15: ...12 Version MDV06U 001IW 202000170150...

Page 16: ......

Reviews: