 WARNINGS FOR PRODUCT INSTALLATION

1. Installation must be performed by an authorized dealer or specialist. Defective installation can

cause water leakage, electrical shock, or fire.

2. Installation must be performed according to the installation instructions. Improper installation

can cause water leakage, electrical shock, or fire.

(

In North America,installation must be performed in accordance with the requirement of NEC

and CEC by authorized personnel only.)

3. Contact an authorized service technician for repair or maintenance of this unit. This appliance

shall be installed in accordance with national wiring regulations.

4. Only use the included accessories, parts, and specified parts for installation. Using non-standard

parts can cause water leakage, electrical shock, fire, and can cause the unit to fail.

5.

6.

 

Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot

support the unit’s weight, or the installation is not done properly, the unit may drop and cause

serious injury and damage.

7.

8.

9.
10.

11.

Do not turn on the power until all work has been completed.
When moving or relocating the air conditioner, consult experienced service technicians for
disconnection and reinstallation of the unit.
How to install the appliance to its support, please read the information for details in "indoor unit
installation" and "outdoor unit installation" sections .

 

For units that have an auxiliary electric heater, 

do not 

install the unit within 1 meter (3 feet) of

any combustible materials.

   

Do not

 install the unit in a location that may be exposed to combustible gas leaks. If

combustible gas accumulates around the unit, it may cause fire.

   

Install drainage piping according to the instructions in this manual. Improper drainage may

cause water damage to your home and property.

Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)

1.  

This air-conditioning unit contains fluorinated greenhouse gasses. For specific information on the

type of gas and the amount, please refer to the relevant label on the unit itself or 

the

“Owner's Manual - Product Fiche ” in the packaging of the outdoor unit. 

(European

Union products only)

.

2.

 

Installation, service, maintenance and repair of this unit must be performed by a certified

technician.

3.

Product uninstallation and recycling must be performed by a certified technician.

4.  

For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO

2

equivalent or more, but of less than 50 tonnes of CO

2

 equivalent, If the system has a leak-

detection system installed, it must be checked for leaks at least every 24 months.

5.

 

When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.

34

Summary of Contents for MB-09N8D6-i

Page 1: ...32 ISTOTNA UWAGA Dziękujemy za zakup naszego produktu Przed rozpoczęciem montażu lub obsługi nowego klimatyzatora dokładnie zapoznaj się z niniejszą instrukcją Zachowaj instrukcję do wykorzystania w przyszłości Urządzenia zawierają fluorowane gazy cieplarniane R32 GWP 675 ...

Page 2: ......

Page 3: ... 0 465 0 843 1 08 SEER W W 8 2 7 4 7 3 6 8 Klasa efektywności energetycznej chłodzenie grzanie A A A A A A A A Roczne zużycie energii chłodzenie 1 kWh rok 107 161 254 360 Wydajność projektowa chłodzenie grzanie kW 2 5 2 3 3 4 2 3 5 3 3 9 7 0 5 4 SCOP W W 4 6 4 6 4 4 Roczne zużycie energii grzanie 2 kWh rok 700 700 1365 1890 Deklarowana wydajność w warunkach projektowych średni sezon grzewczy kW 2 ...

Page 4: ...OQR Xī ZDý áDWZRSDOQ FK VXEVWDQFML Z SRVWDFL DHUR ROL QS ODNLHU GR ZáRVyZ IDUED Z VSUD X 0RĪH WR E ü SU F Qą Z QLHFHQLD RJQLD 1LH ZROQR REVâXJLZDý NOLPDW DWRUD Z SREOLĪX PLHMVF Z NWyU FK PRĪH XODWQLDü VLĊ áDWZRSDOQ JD FLHNL JD X ZRNyá XU ąG HQLD PRJą E ü SU F Qą HNVSOR ML 1LH ZROQR Xī ZDý NOLPDW DWRUD Z DZLOJRFRQ P SRPLHV F HQLX QS áD LHQND OXE SUDOQLD 0RĪH WR VSRZRGRZDü SRUDĪHQLH SUąGHP L GRSURZD...

Page 5: ...DPL F V F ąF PL ĝURGNL WDNLH PRJą VSRZRGRZDü Z QLHFHQLH RJQLD OXE GHIRURZDü REXGRZĊ 8 HĪHOL Z W P VDP P SRPLHV F HQLX RSUyF NOLPDW DWRUD QDMGXMą VLĊ UyZQLHĪ SDOQLNL L LQQH XU ąG HQLD JU HZF H QDOHĪ UHJXODUQLH ZLHWU ü SRPLHV F HQLH DE XQLNQąü QLHGRERUX WOHQX HĪHOL XU ąG HQLH QLH EĊG LH XĪ ZDQH SU H GáXĪV F DV QDOHĪ RGáąF ü MH RG ĨUyGáD DVLODQLD F DVLH EXU QDOHĪ Z áąF ü XU ąG HQLH L RGáąF ü ZW F NĊ ...

Page 6: ...F HQLX XU ąG HQLD QLHNWyUH XU ąG HQLD JG ZáąF RQD MHVW IXQNFMD DSRELHJDMąFD DPDU DQLX QLHNWyUH XU ąG HQLD JG ZáąF RQD MHVW IXQNFMD RGĞZLHĪDQLD QLHNWyUH XU ąG HQLD JG DNW ZRZDQD MHVW IXQNFMD 2 QLHNWyUH XU ąG HQLD JG DNW ZRZDQD MHVW IXQNFMD VWHURZDQLD EH SU HZRGRZHJR QLHNWyUH XU ąG HQLD ZVND XMH ELHĪąFą ZDUWRĞü DVLODQLD WU ELH SUDF ZHQW ODWRUD QD Z ĞZLHWODF X SRMDZL VLĊ WHPSHUDWXUD SRPLHV F HQLD LQQ...

Page 7: ...HQLD Z QLVNLFK WHPSHUDWXUDFK GOD VSHFMDOQ FK PRGHOL VWRVRZDQ FK Z NOLPDFLH WURSLNDOQ P GOD VSHFMDOQ FK PRGHOL VWRVRZDQ FK Z NOLPDFLH WURSLNDOQ P FHOX GDOV HM RSW PDOL DFML Z GDMQRĞFL 3DĔVWZD XU ąG HQLD QDOHĪ Z NRQDü SRQLĪV H F QQRĞFL SR RVWDZLDü GU ZL L RNQD DPNQLĊWH RJUDQLF Dü XĪ FLH HQHUJLL SRSU H VWRVRZDQLH IXQNFML 620 5 7 0 5 21 2 QLH EORNRZDü ZORWyZ OXE Z ORWyZ SRZLHWU D UHJXODUQLH NRQWURORZD...

Page 8: ... 2V F ĊG DQLH HQHUJLL Z áąF QLH Z NOLPDW DWRUDFK IDORZQLNLHP FLVQąü SU FLVN JHDU QD SLORFLH Z FHOX DNW ZRZDQLD IXQN FML RV F ĊG DQLD HQHUJLL XĪ FLH PRF RVWDQLH PQLH M V RQH JRGQLH Z EUDQ P WU EHP JHDU 6 F HJyá QDM GXMą VLĊ Z LQVWUXNFML 6WHURZDQLH L L Z QLHNWyU FK XU ąG HQLDFK 6WHURZDQLH L L SR ZDOD QD VWHURZDQLH NOLPDW DWRUHP SU XĪ FLX WHOHIRQX NRPyUNRZHJR L áąF D L L FHOX X VNDQLD GRVWĊSX GR XU ą...

Page 9: ...K NLHUXQHN QDGPXFKX SRZLHWU D PRĪQD UHJXORZDü D SRPRFą SLORWD SDWU QVWUXNFMD REVáXJL SLORWD 8 8 27 Ą 581 8 1 08 8 3U VWRVRZDQLX WU EX à2 1 OXE 2686 1 QLH QDOHĪ XVWDZLDü QDGPXFKX SRG E W GXĪ P NąWHP Z SLRQLH QD GáXĪV H RNUHV F DVX 0RĪH WR SRZRGRZDü VNUDSODQLH VLH ZRG QD ĪDOX MDFK L ĞFLHNDQLH QD SRGáRJĊ OXE PHEOH 3DWU 5 V 3U VWRVRZDQLX WU EX à2 1 OXE 5 1 XVWDZLHQLH QDZLHZX SRG E W GXĪ P NDWHP Z SLRQ...

Page 10: ...QFLH XGDZDQLD VLĊ QD VSRF QHN QRFQ JG NOLPDW DWRU SUDFXMH ZW U ELH FKáR G HQLD WHPSHUDWXUD ZLĊNV VLĊ R SR JRG LQLH L Z URĞQLH R NROHMQ SR NROHMQHM JRG LQLH JG NOL PDW DWRU SUDFXMH Z WU ELH JU DQLD WHPSHUDWXUD PQLHMV VLĊ R SR JRG LQLH L VSDGQLH R NROHMQ SR NROHMQHM JRG LQLH 3UĊGNRĞü REURWyZ ZHQW ODWRUD MHVW PDáD 8U ąG HQLH XWU PD QRZą WHPSHUDWXUĊ SU H JRG LQ D QD VWĊSQLH IXQNFMD VQX Z áąF VLĊ MHGQR...

Page 11: ...XU ąG HQLD 35 2 6à8 Ą 5ĉ 1Ą 3U HG REVáXJą UĊF Qą QDOHĪ Z áąF ü XU ąG HQLH E Z NRQDü UĊF Qą REVáXJĊ XU ąG HQLD 8QLHĞü SDQHO SU HGQL MHGQRVWNL ZHZQĊWU QHM RUD SU WU PDü JR Z W P SRáRĪHQLX GR PRPHQWX DEORNRZDQLD Z PLHMVFX Z NRU VWDü GUąĪNL SRGSRURZH GR SRGWU PDQLD SDQHOX ORNDOL RZDü SU FLVN 0 18 21752 67 52 1 5ĉ 1 SR SUDZHM VWURQLH VNU QNL Z ĞZLHWOD F HP FLVQąü SU FLVN 0 18 21752 67 52 1 5ĉ 1 UD DE D...

Page 12: ...áRGQLF ą XU ą G HQLD L PRĪH PLHü UyZQLHĪ QLHNRU VWQH VNXWNL GOD GURZLD DOHFDP F V F HQLH OWUD UD QD GZD W JRGQLH 8QLHĞü SDQHO SU HGQL XU ąG HQLD 1DMSLHUZ QDFLVQąü NODSNĊ QD NRĔFX OWUD DE ZROQLü D SLĊFLH XQLHĞü Z JyUĊ D QDVWĊSQLH SRFLąJQąü GR VLHELH FLąJQąü OWU HĞOL OWU SRVLDGD PDá OWU RGĞZLHĪDMąF RGF HSLü JR RG ZLĊNV HJR OWUD F ĞFLü OWU RGĞZLHĪDMąF D SRPRFą RGNXU DF D UĊF QHJR F ĞFLü GXĪ OWU FLHSá...

Page 13: ...5ĉ 1 UD HĞOL SU SRPQLHQLH QLH RVWDQLH UHVHWRZDQH NRG Ä SRQRZQLH SRMDZL VLĊ QD Z ĞZLHWODF X Z PRPHQFLH UHVWDUWRZDQLD XU ąG HQLD 3U SRPQLHQLH R Z PLDQLH OWUD SRZLHWU D 3R JRG LQDFK XĪ WNRZDQLD QD Z ĞZLHWODF X QD MHGQR VWFH ZHZQĊWU QHM SRMDZL VLĊ NRG ÄQ MHVW WR SU SRPQLHQLH R Z PLDQLH OWUD 3R VHNXQGDFK QD Z ĞZLHWODF X RVWDQą SU ZUyFRQH SRSU HGQLH LQIRUPDFMH E UHVHWRZDü SU SRPQLHQLH ZFLVQąü SU FLVN QD...

Page 14: ...NIE na tryb WENTYLACJI Głośna praca jednostki wewnętrznej Powrotowi żaluzji na wylocie powietrza do początkowego ustawienia może towarzyszyć szum powietrza Po pracy w trybie GRZANIA z urządzenia może dochodzić skrzypienie wywołane rozszerzaniem i kurczeniem się elementów jednostki wykonanych z tworzywa sztucznego Jednostki wewnętrzna i zewnętrzna emitują hałas Niskie syczenie słyszalne podczas pra...

Page 15: ... należy skontaktować się z dystrybutorem lub najbliższym centrum obsługi klienta Przedstaw szczegółowy opis usterki urządzenia oraz podaj numer modelu Wykrywanie i usuwanie usterek W przypadku wystąpienia problemu prosimy sprawdzić poniższe punkty przed skontaktowaniem się z serwisem Problem Możliwa przyczyna Rozwiązanie Niska wydajność chłodzenia Ustaw niższą temperaturę Nastawa temperatury może ...

Page 16: ...niczego urządzenia grzewczego Chłodne powietrze dostaje się przez drzwi i okna Upewnij się że wszystkie drzwi i okna są zamknięte podczas pracy urządzenia Mała ilość czynnika na skutek nieszczelności lub długiego użytkowania Sprawdź szczelność usuń przyczynę wycieku jeśli to konieczne i uzupełnij czynnik Kontrolki nieprzerwanie pulsują Klimatyzator może wyłączyć się lub kontynuować bezpieczną prac...

Page 17: ...ZH ZVND DQ P DNáDG LH DMPXMąF P VLĊ ELyUNą NRPXQDOQ FK RGSDGyZ HOHNWURQLF Q FK 3U NXSQLH QRZHJR XU ąG HQLD VSU HGDZFD RGELHU H QLHRGSáDWQLH VWDUH XU ąG HQLH 3URGXFHQW RGELHU H QLHRGSáDWQLH VWDUH XU ąG HQLH 8U ąG HQLH PRĪQD VSU HGDü FHUW NRZDQ P VSU HGDZFRP áRPX 8W OL DFMD XU ąG HQLD Z ODVDFK OXE LQQ P ĞURGRZLVNX QDWXUDOQ P VWDQRZL DJURĪHQLH GOD GUR ZLD L MHVW V NRGOLZD GOD ĞURGRZLVND 1LHEH SLHF QH...

Page 18: ...IXQNFMH 2 FLVQąü L SU WU PDü SU H VHNXQG DE ZáąF ü IXQNFMĊ 5 35 6 02 75 PLDQD WU EX G LDáDQLD Z QDVWĊSXMDF VSRVyE 872 à2 1 2686 1 2 5 1 17 35 6 8UXFKDPLD L DWU PXMH DXWRPDW F Q QDZLHZ ZDKDGáRZ 1DFLĞQLM SU FLVN SR LRPH ZDFKORZDQLH ZáąF VLĊ DXWRPDW F QLH 3U WU PDM SU FLVN VHN ZDFKORZDQLH PLHQL VLĊ QD SLRQRZH 1 67 3U HáąF D IXQNFMH Z QDVWĊSXMąF VSRVyE EUDQ V PERO Z ĞZLHWOL VLĊ ZFLVQąü OXE DE DWZLHUG ...

Page 19: ...U FLVNX WDNLHM IXQNFML QD SLORFLH QLH SU QLHVLH ĪDGQHJR VNXWNX 167 0 1 7 5 R NOLPDW DWRUD GRáąF RQR GZLH EDWHULH 3URVLP R D LQVWDORZDQLH EDWHULL Z SLORFLH SU HG XĪ FLHP VXQąü W OQą SRNU ZĊ SLORWD NLHUXMąF Mą Z Gyá Z FHOX Z HNVSRQRZDQLD NRPRU EDWHULL DLQVWDORZDü EDWHULH ZUDFDMąF XZDJĊ DE GRSDVRZDü ELHJXQ L V PERODPL ZHZQąWU NRPRU VXQąü SRNU ZĊ W OQą QD PLHMVFH 8ZDJL GRW F ąFH EDWHULL VXQąü W OQą SR...

Page 20: ...D XQNFMD QLHGRVWĊSQD GOD WHM MHGQRVWNL ĞZLHWODQLH IXQNFML FLFKHM SUDF ĝ 7 1 21 2 3RMDZLD VLĊ JG MHGQRVWND MHVW ZáąF RQD L QLND JG MHVW Z áąF RQD ĝ 7 1 75 8 2 ĞZLHWOD VLĊ SR DNW ZDFML IXQNFML 2 ĝ 7 1 7 5 NU ZDQLH QLVNLHJR SR LRPX EDWHULL ĝ 7 03 620 5 35ĉ 2ĝ 2 527Ï 17 725 ĞZLHWOD QDVW WHPS GRP ĞOQLH OXE SUĊGNRĞü REURWRZą ZHQW ODWRUD OXE F DVRPLHU SU DVWRVRZDQLX IXQNFML 620 5 Zá 620 5 Z á DNUHV WHPSH...

Page 21: ...VWDZLü ĪąGDQą WHPSHUDWXUĊ NRU VWDMąF SU FLVNX 7 03 Ÿ OXE 7 03 ź FLVQąü SU FLVN 21 2 Z FHOX ZáąF HQLD MHGQRVWNL 35ĉ 2ĝ 2 5272 17 725 QLH PRĪQD QD VWDZLü Z WU ELH DXWRPDW F Q P 75 à2 1 1DFLVQąü SU FLVN 75 02 Z FHOX Z EUDQLD WU EX FKáRG HQLD 1DVWDZLü ĪąGDQą WHPSHUDWXUĊ NRU VWDMąF SU FLVNX 7 03 Ÿ OXE 7 03 ź FLVQąü SU FLVN 1 17 Z FHOX Z EUDQLD SUĊGNRĞFL REURWyZ ZHQW ODWRUD Z DNUHVLH X áąF QLH SU FLVNLH...

Page 22: ...QLH PRĪQD PLHQLDü Z WU ELH 2686 1 à 1 17 725 1DFLVQąü SU FLVN 02 75 Z FHOX Z EUDQLD WU EX ZHQW ODFML FLVQąü SU FLVN 1 17 Z FHOX Z EUDQLD SUĊGNRĞFL REURWyZ ZHQW ODWRUD Z DNUHVLH X áąF QLH SU FLVNLHP 7 03 Ÿ OXE 7 03 ź FLVQąü SU FLVN 21 2 Z FHOX ZáąF HQLD MHGQRVWNL 1LH PRĪQD QDVWDZLDü WHPSHUDWXU Z WU ELH ZHQW ODFML Z SU SDGNX QDVWDZLHQLD QD HNUDQLH Z ĞZLHWODF D SLORWD QLH SRMDZL VLĊ WHPSHUDWXUD 22 ...

Page 23: ... FLVQąü SU FLVN 1 17 Z FHOX Z EUDQLD SUĊGNRĞFL REURWyZ ZHQW ODWRUD Z DNUHVLH X áąF QLH SU FLVNLHP 7 03 Ÿ OXE 7 03 ź FLVQąü SU FLVN 21 2 Z FHOX ZáąF HQLD MHGQRVWNL 6SDGHN WHPSHUDWXU QD HZQąWU PRĪH PLHü QHJDW ZQ ZSá Z QD G LDáDQLH IXQNFML 2 5 1 WDNLFK SU SDG NDFK DOHFDP NRU VWDQLH NOLPDW DWRUD UD HP LQQ PL XU ąG HQLDPL JU HZF PL 23 ...

Page 24: ...UDWXUD VNDĨQLN SR RVWDQLH ZáąF RQ D IXQNFMD EĊG LH DNW ZRZDQD 81 620 5 àĄ 21 7 0 5 2 3U NáDG 1DVWDZLDQLH MHGQRVWNL QD Z áąF HQLH SR JRG LQDFK XQNFMD 7 0 5 2 SR ZDOD QD QDVWDZLHQLH RNUHVX F DVX SR NWyU P MHGQRVWND Z áąF VLĊ DXWRPDW F QLH QS NLHG ZVWDMHP UDQR XQNFMD 7 0 5 2 PRĪH E ü QDVWDZLRQD MHG QLH JG MHGQRVWND MHVW Z WU ELH 21 ZáąF RQD 1DFLVQąü SU FLVN F DVRPLHU D 1D Z ĞZLHWODF X SRMDZL VLĊ L EĊ...

Page 25: ...JRG LQD WR D FKFą 3DĔVWZR DE MHGQRVWND ZáąF áD VLĊ DXWRPDW F QLH R KFą 3DĔVWZR DE G LDáDáD SU H JRG LQ D SRWHP DXWRPDW F QLH Z áąF áD VLĊ R 1DOHĪ ZyZF DV Z NRQDü QDVWĊSXMąFH G LDáDQLD 21 2 21 2 02 02 6 257 6 257 87 87 7 0 5 21 7 0 5 21 7 03 7 03 VHF VHF 7HPS RU 7HPS RU 25 Jednoczesne ustawianie funkcji TIMER ON i TIMER OFF ...

Page 26: ...ąF HQLH VLĊ RE U VXQHN SRQLĪHM ĞZLHWODF SLORWD DVRPLHU MHVW XVWDZLRQ QD àĄ 1 XU ąG HQLD SR JRG LQDFK RG ELHĪąFHM JRG LQ DVRPLHU MHVW XVWDZLRQ QD àĄ 1 XU ąG HQLD SR JRG LQDFK RG ELHĪąFHM JRG LQ LHĪąFD JRG LQD 5R SRF ĊFLH G LDáDQLD HGQRVWND F DVRPLHU D 21 2 JRG LQ SyĨQLHM JRG LQ SyĨQLHM HGQRVWND 26 ...

Page 27: ...U QHM XPRĪOLZL NOLPDW DWRURZL RSW PDOL RZDQLH WHPSHUDWXU ZRNyá L DSHZQLHQLH PDNV PDOQHJR NRPIRUWX 81 6 02 6 1 2SFMRQDOQD DNWHULH SU HQRV RQH Z SRZLHWU X PRJą UR PQDĪDü VLĊ Z ZLO JRFL ZRNyá Z PLHQQLNyZ FLHSáD MHGQRVWNL S U UHJXODUQ P XĪ ZDQLX ZLĊNV RĞü WHM ZLOJRFL Z SDURZXMH 3R QDFLĞQLĊFLX SU FLVNX 6 1 MHGQRVWND Z F ĞFL VLĊ DXWRPDW F QLH NO F V F HQLD WUZD PLQXW SR F P MHGQRVWND Z áą F VLĊ DXWRPDW ...

Page 28: ...E ZSURZDG Lü WU E HQHUJRRV F ĊGQ Z QDVWĊSXMąFHM NROHMQRĞFL Қ GR XĪ FLD HQHUJLL HOHNWU F QHM Қ GR XĪ FLD HQHUJLL HOHNWU F QHM XQNFMD WD MHVW GRVWĊSQD Z áąF QLH Z WU ELH FKáRG HQLD WU ELH G LDáDQLD IXQNFMLJ HDU QD Z ĞZLHWODF X SLORWD EĊGą Z ĞZLHWODQH QDSU HPLHQQLH XĪ FLH HQHUJLL HOHN WU F QHM L QDVWDZLRQD WHPSHUDWXUD 81 35 3U WU PDü SU FLVN SUĊGNRĞFL REURWyZ ZHQW ODWRUD SU H VHNXQG DE DNW ZRZDü RGZR...

Page 29: ...OWNER S MANUAL zymetric pl SPLIT TYPE ROOM AIR CONDITIONER MISSION Smart Xtreme series R 32 ...

Page 30: ......

Page 31: ...t in the use of flammable refrigerants For more details please refer to the Information of servicing or INSTALLATION MANUAL European Disposal Guidelines 46 Manual operation without Remote 40 1 Indoor unit display 36 2 Operating temperature 37 3 Other features 38 CS407U MB R32 GA MIDEA 55 60 R32 675 8 2 A 107 2 5 4 6 A 700 2 3 2 16 0 140 MB 09N8D6 I 0 438 650 675 675 MBT 09N8D6 O MB 12N8D6 I MBT 12...

Page 32: ... burning smell immediately turn off the unit and disconnect the power Call your dealer for instructions to avoid electric shock fire or injury Do not insert fingers rods or other objects into the air inlet or outlet This may cause injury since the fan may be rotating at high speeds Do not use flammable sprays such as hair spray lacquer or paint near the unit This may cause fire or combustion Do no...

Page 33: ...trical outlet with other appliances Improper or insufficient power supply can cause fire or electrical shock If connecting power to fixed wiring an all pole disconnection device which has at least 3mm clearances in all poles and have a leakage current that may exceed 10mA the residual current device RCD having a rated residual operating current not exceeding 30mA and disconnection must be incorpor...

Page 34: ...ppliance to its support please read the information for details in indoor unit installation and outdoor unit installation sections For units that have an auxiliary electric heater do not install the unit within 1 meter 3 feet of any combustible materials Do not install the unit in a location that may be exposed to combustible gas leaks If combustible gas accumulates around the unit it may cause fi...

Page 35: ...llowable pressure When mechanical connectors are reused indoors sealing parts shall be renewed When flared joints are reused indoors the flare part shall be re fabricated UL Standard Requirements When mechanical connectors are reused indoors sealing parts shall be renewed When flared joints are reused indoors the flare part shall be re fabricated IEC Standard Requirements 35 2EMDĞQLHQLH V PEROL XP...

Page 36: ...e Units for 3 seconds when TIMER ON is set FRESH SWING TURBO or SILENCE features are turned on when Fresh feature is activated some units for 3 seconds when TIMER OFF is set FRESH SWING TURBO or SILENCE features are turned off when defrosting when anti cold air feature is turned on when unit is self cleaning some units when defrost feature is activated Display Code Meanings Displays temperature op...

Page 37: ...F 0 C 50 C 32 F 122 F 0 C 52 C 32 F 126 F For special tropical models 0 C 52 C 32 F 126 F For special tropical models 15 C 50 C 5 F 122 F For models with low temp cooling systems To further optimize the performance of your unit do the following Keep doors and windows closed Limit energy usage by using TIMER ON and TIMER OFF functions Do not block air inlets or outlets Regularly inspect and clean a...

Page 38: ...nction can only be activated via remote control And the Sleep function is not available in FAN or DRY mode Press the SLEEP button when you are ready to go to sleep When in COOL mode the unit will increase the temperature by 1 C 2 F after 1 hour and will increase an additional 1 C 2 F after another hour When in HEAT mode the unit will decrease the temperature by 1 C 2 F after 1 hour and will decrea...

Page 39: ...set louver at too vertical an angle for long periods of time This can cause water to condense on the louver blade which will drop on your floor or furnishings When using COOL or HEAT mode setting the louver at too vertical an angle can reduce the performance of the unit due to restricted air flow Setting horizontal angle of air flow CAUTION Do not put your fingers in or near the blower and suction...

Page 40: ...ED COOLING mode 5 Press the MANUAL CONTROL button a third time to turn the unit off 6 Close the front panel CAUTION The manual button is intended for testing purposes and emergency operation only Please do not use this function unless the remote control is lost and it is absolutely necessary To restore regular operation use the remote control to activate the unit Unit must be turned off before man...

Page 41: ...also be bad for your health Make sure to clean the filter once every two weeks 1 Lift the front panel of the indoor unit 2 Grip the tab on the end of the filter lift it up then pull it towards yourself 3 Now pull the filter out 4 If your filter has a small air freshening filter unclip it from the larger filter Clean this air freshening filter with a hand held vacuum 5 Clean the large air filter wi...

Page 42: ...n Use If you plan not to use your air conditioner for an extended period of time do the following Clean all filters Turn on FAN function until unit dries out completely Turn off the unit and disconnect the power Remove batteries from remote control Maintenance Pre Season Inspection After long periods of non use or before periods of frequent use do the following Check for damaged wires Clean all fi...

Page 43: ...ss The unit changes from COOL HEAT mode to FAN mode The indoor unit makes noises A rushing air sound may occur when the louver resets its position A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit s plastic parts Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is normal and is caused by refrigerant...

Page 44: ...est customer service center Provide them with a detailed description of the unit malfunction as well as your model number Troubleshooting When troubles occur please check the following points before contacting a repair company Problem Possible Causes Solution Poor Cooling Performance Temperature setting may be higher than ambient room temperature Lower the temperature setting The heat exchanger on...

Page 45: ...erformance The outdoor temperature is extremely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows are closed during use Low refrigerant due to leak or long term use Check for leaks re seal if necessary and top off refrigerant Indicator lamps continue flashing The unit may stop operation or continue to run safely If the indicator la...

Page 46: ...g options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take back the old appliance free of charge Sell the appliance to certified scrap metal dealers Special notice Disposing of this appliance in the forest or other natural surroundings endangers y...

Page 47: ...ndoor unit s LED display and air conditioner buzzer on and off which create a comfortable and quiet environment Under this mode the display will illuminate for 10 seconds while adjusting the mode set temperature or fan speed etc MODE Scrolls through operation modes as follows Timer on T g imer off Sel g f Clean Before you begin using your new air conditioner make sure to familiarize yourself with ...

Page 48: ...ATTERIES INSTALLING REMOTE CONTROL HOLDER Your air conditioning unit comes with two AAA batteries Put the batteries in the remote control before use 1 2 Remove the back cover from the remote control exposing the battery compartment Insert the batteries paying attention to match up the and ends of the batteries with the symbols inside the battery compartment 3 Install the back cover on The remote c...

Page 49: ...elected fan speed TIMER ON display Displays when TIMER ON is set TIMER OFF display Displays when TIMER OFF is set Temperature Timer Fan speed display Displays the set temperature by default or fan speed or timer setting when using TIMER ON OFF functions Temperature range 16 30 o C 60 86 O F Timer setting range 0 24 hours Fan speed setting range AU 100 ECO display Displays when ECO feature is activ...

Page 50: ...will automatically select the COOL FAN HEAT or DRY mode based on the set temperature SETTING TEMPERATURE AUTO operation 1 Press the MODE button to select Auto mode 2 Set your desired temperature using the Temp or Temp button 3 Press the ON OFF button to start the unit NOTE FAN SPEED can t be set in Auto mode COOL operation How To Use The Basic Functions The operating temperature range for units is...

Page 51: ...peration dehumidifying FAN operation 2 ress the MODE button to select FAN mode ress the FAN button to select the fan speed in a range of Au 100 in conjunction with Temp or Temp button Press the ON OFFbutton to start the unit How To Use The Basic Functions 1 3 2 NOTE You can t set temperature in FA N mode As a result your remote control s LCD screen will not display temperature Mode SET Mode SET 51...

Page 52: ... the unit 1 ress the MODE button to select HEAT mode 2 et your desired temperature using the Temp or Temp button 3 How To Use The Basic Functions Mode SET NOTE As outdoor tempe rature drops the performance of your unit s HEAT function may be affected In such instances we recommend using this air conditioner in conjunction with other heating appliance 52 ...

Page 53: ...e period that you set and an h indicating hours will appear on the display Note This number indicates the amount of time after the current time that you want the unit to turn on For example if you set TIMER ON for 2 5 hours 2 5h will appear on the screen and the unit will turn on after 2 5 hours TIMER ON function The TIMER ON function allows you to set a period of time after which the unit will au...

Page 54: ...remote control will then return to the temperature display The indicator remains on and this function is activated The TIMER OFF function allows you to set a period of time after which the unit will automatically turn off such as when you wake up x10 ON OFF MODE FAN SHORT CUT TIM ER ON TIM ER F OF TEMP SLEEP 3sec SET or Press the SETbutton until an indicator Timer off appears and flashes By defaul...

Page 55: ...e current time For example say that the current time is 1 00 PM and you want the unit to turn on automatically at 7 00 PM You want it to operate for 2 hours then automa tically turn off at 9 00 PM Do the following ON OFF ON OFF MODE MODE SHORT SHORT CUT CUT TIM ER ON TIM ER ON TEMP TEMP 3 3 sec sec 4 8 3 7 X12 X16 2 6 1 5 SET SET or or 55 ...

Page 56: ...n turn off see the figure below Your remote display Timer is set To turn ON 6 hours from current time Timer is set to turn OFF 8 hours from current time Current time 1PM 2PM 3PM 4PM 5PM 6PM 7PM 8PM 9PM Timer starts Unit turns Unit turns ON OFF 6 hours later 8 hours later 56 ...

Page 57: ...elect TURBO feature in HEAT mode the unit will blow heat air with strongest wind setting to jump start the heating process Airborne bacteria can grow in the moisture that condenses around heat exchanger in the unit With regular use most of this moisture is evaporated from the unit When the SELF CLEAN feature is activated your unit will clean itself automatically After cleaning the unit will turn o...

Page 58: ...O C If the set temperature is above 24 O C press the ECO button the fan speed will change to Auto the set temperature will remain unchanged NOTE Pressing the ON OFF button modifying the mode or adjusting the set temperature to less than 24O C will stop ECO operation Under ECO operation the set temperature should be 24O C or higher it may result in insufficient cooling If you feel uncomfortable jus...

Page 59: ......

Page 60: ...IO0083M042018 ...

Reviews: