Service Manual_2020-V1.0
21
6.5 Welding point in the compressor case
Welding point
Pipe outer diameter (mm)
1-Inlet of right condenser tube and outlet of venting
connection tube
Steel pipe:
Φ4.0
Steel pipe:
Φ4.0
2-Inlet of anti-condensation tube and outlet of right condenser
tube
Steel pipe:
Φ4.0
Steel pipe:
Φ4.0
3-Outlet of anti-condensation tube and inlet of left condenser
tube
Steel pipe:
Φ4. 0
Copper pipe:
Φ4.0
4-Outlet of left condenser tube and inlet of dry filter
Steel pipe:
Φ4. 0
Copper pipe:
Φ5.0
5-Outlet of dry filter and inlet of freezer capillary
Copper pipe: Φ2.8
Copper pipe: Φ1.8
6-Heat transition tube and Suction connection tube
Copper pipe:
Φ6.0
Copper pipe:
Φ6.0
7-Suction connection pipe and compressor intake tube
Copper pipe:
Φ6.0
Copper pipe:
Φ8.17
8-Compressor outlet tube and inlet of venting connection tube Copper pipe:
Φ6.17
Steel pipe:
Φ4.0
9-Compressor process tube and refrigerant filling tube
Copper pipe:
Φ8.17
Copper pipe:
Φ6.0
Summary of Contents for HS-625FWEN
Page 5: ...Service Manual_2020 V1 0 5 1 Significant update notes None...
Page 16: ...Service Manual_2020 V1 0 16 5 2 Circuit diagram A Ambient temperature...
Page 18: ...Service Manual_2020 V1 0 18 5 4 Inverter board terminal connection diagram None...
Page 41: ...Service Manual_2020 V1 0 41 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Page 42: ...Service Manual_2020 V1 0 42...
Page 43: ...Service Manual_2020 V1 0 43 11 2 No working of compressor...
Page 44: ...Service Manual_2020 V1 0 44 11 3 Inside frosting no defrosting...
Page 45: ...Service Manual_2020 V1 0 45 11 4 Inside frosting no defrosting Maintenance guidelines...
Page 46: ...Service Manual_2020 V1 0 46 11 5 Light is not on...
Page 47: ...Service Manual_2020 V1 0 47 11 6 Fan failure 11 7 Defective defrost circuit...
Page 48: ...Service Manual_2020 V1 0 48 11 8 Noise 11 9 Air duct not operated Option...
Page 49: ...Service Manual_2020 V1 0 49 11 10 Ice maker not make ice Option...