Service Manual_2020-V1.0
27
7.6 Compressor case
1
)
Remove the air duct components in freezing
chamber.
2
)
Disconnect all connectors.
3
)
Remove the welding on inlet and outlet tubes.
4
)
Remove two screws which are used to fix the
evaporator and remove the evaporator.
Components on the evaporator
Defrost heater with defrost sensor and fuse, it can be
replaced separately.
1
)
Cut off wiring terminal
2
)
Cut off the band which fixes the sensor
3
)
Cut off the band which fixes the fuse
4
)
Separate the sensor and the evaporator
Take off the defrost heater from the supporting plate of
evaporator
Summary of Contents for HS-312FWEN
Page 5: ...Service Manual_2020 V1 0 5 1 Significant update notes None...
Page 34: ...Service Manual_2020 V1 0 34 7 9 Variable frequency driver board None 7 10 Water dispenser NONE...
Page 44: ...Service Manual_2020 V1 0 44 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Page 45: ...Service Manual_2020 V1 0 45...
Page 46: ...Service Manual_2020 V1 0 46 11 2 No working of compressor...
Page 47: ...Service Manual_2020 V1 0 47 11 3 Inside frosting no defrosting...
Page 48: ...Service Manual_2020 V1 0 48 11 4 Inside frosting no defrosting Maintenance guidelines...
Page 49: ...Service Manual_2020 V1 0 49 11 5 Light is not on...
Page 50: ...Service Manual_2020 V1 0 50 11 6 Fan failure 11 7 Defective defrost circuit...
Page 51: ...Service Manual_2020 V1 0 51 11 8 Noise 11 9 Air duct not operated Option...
Page 52: ...Service Manual_2020 V1 0 52 11 10 Ice maker not make ice Option...