This electric water heater should be installed at the place without sunshine or rain spray. 

Please cut off power supply if not use for long time.

Please blow down the water for about 10 seconds to drain away the impurities in the pipe before 

connecting the water source to the electric water heater to avoid blockage of water heater.

If long time no use the unit, check the water heater first before use. Electrify after the water 

flows out stably.

Do not spray water to air switch or heater body directly, to avoid moist.

Please cut off the power in the weather of thunder and rain to avoid damaging the water heater.

If not use for long period of time, please cut off water inlet to prolong the lifespan of the water 

heater.

Check  the  power cord connecting  terminals  frequently  to  make  sure  that they are well  and 

reliably contacted, no overheating phenomenon, and grounding is good or not.

Disassembly shower head and sealing ring with filter to clean periodically.

DECLARATION: 

this water heater can only be maintained by authorized service personnel, 

incorrect installation and using method may cause serious injury or loss of property.

5. MAINTENANCE

 

WARNING

Do cut off power supply before maintenance, to avoid danger like electric shock.

!

Summary of Contents for DSK45V

Page 1: ...g and operating your water heater please read this manual carefully and keep it for future reference The diagram above is just for reference Please take the appearance of the actual product as the sta...

Page 2: ...e 9 6 Troubleshooting 10 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electrica...

Page 3: ...y or death Do cut off power supply before any maintenance Any maintenance or adjustment towards this product by non professional is highly prohibited The damage power cord must be replaced by a good p...

Page 4: ...CT INTRODUCTION Model Rated Voltage Rated Frequency Rated Power Rated Current Dia Of Wire Code Air Switch Rated Pressure Minimum Flow Rate Minimum Pressure Maximum Pressure Protection Class Water Proo...

Page 5: ...Silicon Control Main Control Board Relay Relay Flow Sensor Temperature Sensor Terminal Block G CN1 CN4 CN6 CN2 CN3 CN5 T1 T2 ELCB Terminal block Indicator light board Main control board Silicon contro...

Page 6: ...ain Switch Knob and Power Knob to make it free Remove the front plate gently Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire p...

Page 7: ...rive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cover...

Page 8: ...r must be used when install the unit Blue marker stands for water inlet red marker stands for water outlet Do not overexert to avoid damaging the water heater NOTE A private power cord should be used...

Page 9: ...y Leakage Protection When the electricity leakage testing circuit is working normally if the leakage current is bigger than certain value between 7 5mA and 15mA the indicator light will keep flickerin...

Page 10: ...ist Please cut off the power in the weather of thunder and rain to avoid damaging the water heater If not use for long period of time please cut off water inlet to prolong the lifespan of the water he...

Page 11: ...hermal cut out acts 4 Electricity leaks 1 Switch is off 2 Heating element error 3 PCB error 4 Water pressure is too low can t start the unit 1 The running water supply is cut off 2 The inlet valve of...

Page 12: ...The product is subject to change without notice Please keep this manual properly...

Reviews: