6
3.3 Water Heater Installation
3.4 Plumbing Connection
①
②
③
④
⑤
NOTE
The installation position of neutral line (blue), live line (brown/red) and earth line
(green/yellow) should be corresponding to the other end on wiring terminals.
Make sure the distance between the unit and surrounding wall is not less than 300mm, so
that to have enough space for maintenance purpose.
Determine the position of four fixing screws (attached with the unit), make four holes with
corresponding depth in the wall by means of a drill and drive a wall plug into the hole.
Drive in the screws on the top and ensure certain distance between screw head and wall
(See Fig.1)
Mount the unit on the wall and tighten with two screws at bottom, connect the wires and
install top cover with the screws.
Determine installation position of the unit according to length of power cord / position
of air switch (Distance between bottom and
floor should be ≥1.6m).
①
②
Shower flexible tube should be connected with water outlets and shower head separately,
attached sealing ring should be used at end face.
Water valve with filter should be installed at water inlet of the unit, sealing ring with filter
should be used at end face. (See Fig.2).
(Fig.1)
WARNING
Metallic / chromed hose and conductive control valve shall not be used.
!