background image

2

1. CAUTIONS

To prevent personal injury, injury to others and property damage, the instructions below must be followed. 

Incorrect operation due to failure to follow instructions will cause harm or damage. Installation must be 

carried out by a qualified personnel and in compliance to the local authority regulations.

WARNING

Special Cautions

The water heater should be earthed before use. Please ensure that the resistance of 

household earth wire is <4Ω. Using water heater without earthed is highly prohibited.

!

This water heater is for household, and it can be installed wherever place that need hot water, 

eg. Washing hands, dishes or foods, and so on. (Multi directional water supply is not available).

Plug is not used for this water heater; The appliance must be connected directly with power 

switch that comes with leakage-protection. Please distinguish live line (red/brown), neutral line 

(blue) and earth line (green/yellow) during installation. 

Do check whether the amperes of the household wiring enough before installation, and 

dedicated circuit must be used when installation.

Before installing this water heater, check and confirm the earth electrode on the socket is reliably 

earthed, without electricity.

The water heater should be installed indoor

where temperature keeps over 0

. If the water inside 

of water heater has been frozen, it’s forbidden to turn on water heater before the ice meltdown.

Hot water from appliance may cause scald, please test the temperature of the hot water before use.

The distance between water heater installed and water output should be as nearby as possible 

to avoid loss of heat.

The electric water heater may be damaged if the water hardness is too high. To ensure longer 

product lifespan, please install and put it into use on condition that the local water hardness is 

less than 450mg/L (CaCO3)

In time of lightning/thunder, switch “Off” the Miniature Circuit Breaker (MCB) in advance to 

protect the water heater against possible damage.

Inspection on the built-in ELCB (once a month) to avoid a hazard to users such as damage to 

property, serious injury or death.

Do cut-off power supply before any maintenance. Any maintenance or adjustment towards this 

product by non-professional is highly prohibited.

The damage power cord must be replaced by a good power cord provided by the manufacturer, 

and the replacement should be done by a qualified technician or   engineer  or  professionals  of 

the similar products.

In order to avoid a hazard due to inadvertent resetting of the Earth Leakage Circuit Breaker 

(ELCB), this appliance must not be supplied through an external switching device, such as timer 

or connected to a circuit that is regularly switched “On” and “Off” by the utility.

Water heater is equipped with adjustable flow capacity safety valve. For safety use, please do 

not change its installation location and do not block its water outlet.

The heater must be permanently connected to the electricity supply, direct from the consumer unit via 

a double poles linked switch with a minimum contact gap of 3mm in both poles. The switch must be 

readily accessible and clearly identifiable and out of reach of person using a fixed bath or shower. The 

wiring must be connected to the switch without the use of a plug or socket outlet.

Appliance is not to be used by children or persons with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction. Children being supervised not to play with appliance.

The shower head must be descaled regularly.When the shower is used by someone such as 

child, old person, sick person and physical handicapped person, the concern person is kindly 

requested to pay attention and check the shower temperature by using hand from time to time.

For any improper installation and incorrect operation of this product, our company will not be 

liable for any responsibility.

Summary of Contents for DSK38P5

Page 1: ...ase take the appearance of the actual product as the standard Instruction Manual For Model DSK45P5 DSK38P5 Thank you very much for purchasing our water heater Before installing and operating your water heater please read this manual carefully and keep it for future reference ...

Page 2: ...ce 9 6 Troubleshooting 10 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electrical water heater to make full use of its excellent performances Please do preserve the instruction manual for future reference ...

Page 3: ...nder switch Off the Miniature Circuit Breaker MCB in advance to protect the water heater against possible damage Inspection on the built in ELCB once a month to avoid a hazard to users such as damage to property serious injury or death Do cut off power supply before any maintenance Any maintenance or adjustment towards this product by non professional is highly prohibited The damage power cord mus...

Page 4: ...ass Products Size Knob Quantity I DSK38P5 DSK45P5 2 1 Main control board Terminal block Indicator light board Key board Silicon control Flow sensor Marker for water inlet Water inlet Wire pressing board Thermal cut out Heating elements assembly Stainless steel circlip Temperature sensor Marker for wateroutlet Water outlet Red Blue PRODUCT STRUCTURE FOR DSK P5 4500W 20 5A 2 5mm 25A 220V 50Hz 3800W ...

Page 5: ...5 Indicator Light And Key Board Thermal Cut Out L N E Red Blue Yellow Green Temperature Adjusting Board Heating Elements Silicon Control Main Control Board Relay Relay Flow Sensor Temperature Sensor Terminal Block ELCB CN1 CN3 CN5 PE CN2 CN1 CN2 G T1 T2 ...

Page 6: ...b to make it free Remove the front plate gently Remove the power cord wire pressing plate and keep the screws Step 3 Step 4 Step 5 Step 6 Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire pressing plate with screws to primary position ensure that the power cord not be pulled out more than 60N Screw the power cord into the jack...

Page 7: ...ive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cover with the screws Determine installation position of the unit according to length of power cord position of air switch Distance between bottom and floor should be 1 6m Shower flexible tube should be con...

Page 8: ...exert to avoid damaging the water heater NOTE A private power cord should be used for this unit After connecting to electric network please check the earth condition and make sure the earth resistance is 4Ω After all the plumbing is finished connecting open water inlet valve of the product and supply water to the unit to drain away air inside until there is stable water flow comes out from shower ...

Page 9: ...lectricity leakage testing circuit is working normally if the leakage current is bigger than certain value between 7 5mA and 15mA EARTH ELCB and POWER indicator light will be twinkling flicker no heating it can only be used after the failure is excluded When electricity leakage is tested red and green indicator lights are all off stop heating 4 5 To Adjust Water Temperature Rotate the handle of wa...

Page 10: ...st Please cut off the power in the weather of thunder and rain to avoid damaging the water heater If not use for long period of time please cut off water inlet to prolong the lifespan of the water heater Check the power cord connecting terminals frequently to make sure that they are well and reliably contacted no overheating phenomenon and grounding is good or not Disassembly shower head and seali...

Page 11: ...ent 1 2L min PCB error 4 Impurities clogging the flow sensor of the rotor 1 The running water supply is cut off 2 The inlet valve of running water is not open 1 Water pressure is not stable 2 Outlet water temperature is too high overheating protection again and again Electricity leaks Temperture sensor is broken Change the temperture sensor SYMPTOMS The heating indicator light is off and the outle...