Instant Electric Water Heater

The diagram above is just for reference. Please take the

appearance of the actual product as the standard. 

Instruction Manual

For Model: DSK45P5

                  DSK38P5

Thank you very much for purchasing our water heater. 

Before installing and operating your water heater, please 

read this manual carefully and keep it for future reference.

Summary of Contents for DSK38P5

Page 1: ...ase take the appearance of the actual product as the standard Instruction Manual For Model DSK45P5 DSK38P5 Thank you very much for purchasing our water heater Before installing and operating your water heater please read this manual carefully and keep it for future reference ...

Page 2: ...ce 9 6 Troubleshooting 10 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electrical water heater to make full use of its excellent performances Please do preserve the instruction manual for future reference ...

Page 3: ...nder switch Off the Miniature Circuit Breaker MCB in advance to protect the water heater against possible damage Inspection on the built in ELCB once a month to avoid a hazard to users such as damage to property serious injury or death Do cut off power supply before any maintenance Any maintenance or adjustment towards this product by non professional is highly prohibited The damage power cord mus...

Page 4: ...ass Products Size Knob Quantity I DSK38P5 DSK45P5 2 1 Main control board Terminal block Indicator light board Key board Silicon control Flow sensor Marker for water inlet Water inlet Wire pressing board Thermal cut out Heating elements assembly Stainless steel circlip Temperature sensor Marker for wateroutlet Water outlet Red Blue PRODUCT STRUCTURE FOR DSK P5 4500W 20 5A 2 5mm 25A 220V 50Hz 3800W ...

Page 5: ...5 Indicator Light And Key Board Thermal Cut Out L N E Red Blue Yellow Green Temperature Adjusting Board Heating Elements Silicon Control Main Control Board Relay Relay Flow Sensor Temperature Sensor Terminal Block ELCB CN1 CN3 CN5 PE CN2 CN1 CN2 G T1 T2 ...

Page 6: ...b to make it free Remove the front plate gently Remove the power cord wire pressing plate and keep the screws Step 3 Step 4 Step 5 Step 6 Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire pressing plate with screws to primary position ensure that the power cord not be pulled out more than 60N Screw the power cord into the jack...

Page 7: ...ive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cover with the screws Determine installation position of the unit according to length of power cord position of air switch Distance between bottom and floor should be 1 6m Shower flexible tube should be con...

Page 8: ...exert to avoid damaging the water heater NOTE A private power cord should be used for this unit After connecting to electric network please check the earth condition and make sure the earth resistance is 4Ω After all the plumbing is finished connecting open water inlet valve of the product and supply water to the unit to drain away air inside until there is stable water flow comes out from shower ...

Page 9: ...lectricity leakage testing circuit is working normally if the leakage current is bigger than certain value between 7 5mA and 15mA EARTH ELCB and POWER indicator light will be twinkling flicker no heating it can only be used after the failure is excluded When electricity leakage is tested red and green indicator lights are all off stop heating 4 5 To Adjust Water Temperature Rotate the handle of wa...

Page 10: ...st Please cut off the power in the weather of thunder and rain to avoid damaging the water heater If not use for long period of time please cut off water inlet to prolong the lifespan of the water heater Check the power cord connecting terminals frequently to make sure that they are well and reliably contacted no overheating phenomenon and grounding is good or not Disassembly shower head and seali...

Page 11: ...ent 1 2L min PCB error 4 Impurities clogging the flow sensor of the rotor 1 The running water supply is cut off 2 The inlet valve of running water is not open 1 Water pressure is not stable 2 Outlet water temperature is too high overheating protection again and again Electricity leaks Temperture sensor is broken Change the temperture sensor SYMPTOMS The heating indicator light is off and the outle...

Page 12: ...www midea com global ...