Failures

Reasons

Treatment

The heating indicator

light is off.

Failures of the temperature

controller.

Contact with the professional

personnel for repair.

Contact with the professional

personnel for repair.

No water coming out 

of the hot water outlet.

The water temperature

is too high.

Water leak.

1. The running water supply

    is cut off.

2. The hydraulic pressure is

    too low.

3. The inlet valve of running

    water is not open.

1. Wait for restoration of 

    running water supply.

2. Use the heater again 

    when the hydraulic 

    pressure is increased.
3. Open the inlet valve of 

    running water.

Failures of the temperature

control system.
Seal problem of the joint of 

each pipe.

Seal up the joints.

Summary of Contents for D15-20VA

Page 1: ...take the appearance of the actual product as the standard Congratulations You are now a proud owner of Midea water heater We assure you that this product conforms to the highest standards of quality...

Page 2: ...mage or malfunction caused by wrong installation or failing to comply with following instructions included in this pamphlet For more detailed installation and maintenance guidelines please refer to be...

Page 3: ...the heater can not be switched on until it has been filled fully with water When filling the water at least one of the outlet valves at the outlet of the heater must be opened to exhaust the air This...

Page 4: ...L represents the rated power 100W represents the pattern code eg A B C represents the extension of pattern eg 1 2 3 2 2 Technical Performance Parameters Fig 1 Hot water Cold water Pressure relief valv...

Page 5: ...t structure 2 4 Internal Wire Diagram Note All dimensions are in mm 15L A B C D 380 380 312 66 WIRING DIAGRAM C A B D E N L Q Q Heating Element Heating Indicator light Thermal Cut Out Thermostat Power...

Page 6: ...ipe part is G1 2 The massive pressure of inlet should use Pa as the unit The minimum pressure of inlet should use Pa as the unit Connection of pressure relief valve with the heater on the inlet of the...

Page 7: ...rance not less than 0 2m on the right side of the electric heater to convenient the maintenance of the heater if necessary If the users want to realize a multi way supply system refer to the method sh...

Page 8: ...s up the thermostat will automatically control the temperature When the water temperature inside the heater has reached the set temperature it will switch off automatically when the water temperature...

Page 9: ...e performed by special maintenance services You can ask the seller for address of the nearest service center 5 MAINTENANCE WARNING Do cut off power supply before maintenance to avoid danger like elect...

Page 10: ...ct with the professional personnel for repair Contact with the professional personnel for repair No water coming out of the hot water outlet The water temperature is too high Water leak 1 The running...

Page 11: ...The product is subject to change without notice Please keep this manual properly...

Reviews: