2

Before installing this water heater,check and confirm that the earthing on the supply socket is 

reliably grounded. Otherwise, the electrical water heater can not be installed and used. Do not use 

extension boards. Incorrect installation and use of this electrical water heater may result in serious 

injuries and loss of property.

Special Cautions

1. CAUTIONS

The water heater is not intended for use by persons  (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instructions concerning use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the heater.

The wall in which the electrical water heater is installed must be able to bear the load more than 

two times of the heater filled fully with water without distortion and cracks. Otherwise, other 

strengthening measures must be adopted.

The supply socket must be earthed reliably. The installation height of the supply socket must not 

be lower than 1.8m. The rated current of the socket must not be lower than 16A. The socket and 

plug must be kept dry to prevent electrical leakage. If the flexible power supply cord is damaged, the 

special supply cord provided by the manufacturer must be selected, and replaced by the professional 

maintenance personnel.

The maximum inlet water pressure is 0.5MPa; the minimum inlet water pressure is 0.1MPa, if this 

is necessary for the correct operation of the appliance.

When using the heater for the first time (or the first use after maintenance), the heater can not be 

switched on until it has been filled fully with water. When filling the water, at least one of the outlet 

valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after 

the heater has been filled fully with water.

The pressure relief valve attached with the heater must be installed at the cold water inlet of this 

heater, and make sure it is not exposed in the foggy. The water may be outflowed from pressure 

relief valve, so the outflow pipe must open wide in the air. In order to drain away the water inside 

the inner container, it can be drained away from the pressure release valve. Twist the thread screw 

of the pressure release valve off, and lift the drain handle upwards(See Fig.1) . The drainage pipe 

connected to the pressure release hole must be kept sloping downwards and in a frost-free 

environment. The water may drip from the discharge pipe of the pressure-relief device and that this 

pipe must be left open to the atmosphere.

During heating, there may be drops of water dripping from the pressure release hole of the 

pressure relief valve, this is a normal phenomenon. The pressure release hole shall not be blocked 

under no circumstances, otherwise, the heater may get damaged, even resulting in accidents. If 

there is a large amount of water leak, please contact customer care center for repair. 

The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not 

be blocked.

Since the water temperature inside the heater can reach up to 75

, the hot water must not be 

exposed to human bodies when it is initially used. Adjust the water temperature to a suitable 

temperature to avoid scalding.

If any parts and components of this electrical water heater are damaged please contact customer 

care center for repair.

Summary of Contents for D10-20VD

Page 1: ...e actual product as the standard Midea Storage Electric Water Heater Instruction Manual Model D10 20VD Thank you very much for purchasing our water heater Before installing and operating your water he...

Page 2: ...mage or malfunction caused by wrong installation or failing to comply with following instructions included in this pamphlet For more detailed installation and maintenance guidelines please refer to be...

Page 3: ...the heater can not be switched on until it has been filled fully with water When filling the water at least one of the outlet valves at the outlet of the heater must be opened to exhaust the air This...

Page 4: ...y L represents the rated power 100W represents the pattern code eg A B C represents the extension of pattern eg 1 2 3 2 2 Technical Performance Parameters Fig 1 Hot water Cold water Pressure relief va...

Page 5: ...tructure 2 4 Internal Wire Diagram WIRING DIAGRAM E N L Q Q Heating Element Heating Indicator light Thermal Cut Out Thermostat Power Indicator Brown Blue Yellow Green Note All dimensions are in mm D10...

Page 6: ...ipe part is G1 2 The massive pressure of inlet should use Pa as the unit The minimum pressure of inlet should use Pa as the unit Connection of pressure relief valve with the heater on the inlet of the...

Page 7: ...rance not less than 0 2m on the right side of the electric heater to convenient the maintenance of the heater if necessary If the users want to realize a multi way supply system refer to the method sh...

Page 8: ...If the indicator lights up the thermostat will automatically control the temperature When the water temperature inside the heater has reached the set temperature it will switch off automatically when...

Page 9: ...e performed by special maintenance services You can ask the seller for address of the nearest service center 5 MAINTENANCE WARNING Do cut off power supply before maintenance to avoid danger like elect...

Page 10: ...ct with the professional personnel for repair Contact with the professional personnel for repair No water coming out of the hot water outlet The water temperature is too high Water leak 1 The running...