The electrical  storage  water  heater 

D10-15VDO 

of  the  company 

Midea 

was tested  with  a 

declared load profile of the size 

that correspond to the water heating efficiency class 

The product fulfills and corresponds to the requirements of the commission  regulation standards (No 

814/2013) for electrical storage water heater and achieved a water heating energy efficiency of 

In accordance with Annex

 Enercy Efficiency Classes article 1  of the commission regulation (No 

812/2013) 
The  evaluation  of  the  result  of  this  report  with  respect  of  conformity  with  the  related  commission 

regulation (No 812/2013 and 814/2019) is only a part of the  conformity assessment to achieve the 

ErP-Label.  
Electricity consumption 

Q

elec

water heating energy efficiency 

η

wh

 and mixed water at 40

℃(

V40

 

“XXS” 

“A” 

η

wh

=36% 

 
 

 

 

kWh 
kWh 
kWh 
kWh 
kWh 

 

 

kg 

kWh 

 

kWh 

 

 

 

 

 


Description 

Parameter 

Value 

Unit 

k-Value 

k

Smart control compliance 

smart 

Smart control factor 

SCF 

Conversion coefficient 

CC 

Ambient correction term 

Q

cor

 

Referenct energy 

Q

ref

 

Useful energy content 

Q

H2O

 

Correction ratio of reference and useful energy 

Q

ref/

Q

H2O

 

Daily electricity consumption (measured) 

Q

test_elec

 

Water temperature at the beginning of the 24h measurement cycle 

 

T3 

Water temperature at the end of the 24h measurement cycle 

T5 

Storage volume 

M

act

 

Storage volume 

C

act

 

Daily electricity consumption (corrected) 

Q

elec

 

Water heating energy efficiency 

η

wh

 

Annual Electricity Consumption 

AEC 

Water heating energy efficiency class 

 

 

Water temperature without tapping 

T

set

 

Average water temperature of outlet warm water 

θ

'

p

 

Average water temperature of inlet cold water 

θ

c

Normalised value of the average temperature 

θ

p

 

Volume that delivered water of at least 40

 

V

40exp

 

Calculated volume that delivered hot water of at least 40

 

V

40

 

0.23

0
0

2.5

-0.173

2.1

2.131
0.985
2.469

48.7
51.4
10.3
10.3

2.401

36.0

512

A

48

46.4
10.4
46.4

8
9

Summary of Contents for D10-15VDO

Page 1: ...ction Manual Congratulations You are now a proud owner of Midea water heater We assure you that this product conforms to the highest standards of quality Before installing and operating your water hea...

Page 2: ...used by wrong installation or failing to comply with following instructions included in this pamphlet For more detailed installation and maintenance guidelines please refer to below chapters TABLE OF...

Page 3: ...the heater can not be switched on until it has been filled fully with water When filling the water at least one of the outlet valves at the outlet of the heater must be opened to exhaust the air This...

Page 4: ...arameters Fig 1 Hot water Cold water Pressure relief valve Thread screw Drain handle Pressure release hole Hot water Cold water Pressure relief valve D10 15VDO D10 15VDU Rated Voltage ACV 220 240 220...

Page 5: ...re Diagram WIRING DIAGRAM E N L Q Q Heating Element Heating Indicator light Thermal Cut Out Thermostat Power Indicator Brown Blue Yellow Green Note All dimensions are in mm D10 15VD D15 15VD A B C D 3...

Page 6: ...de on lock the water heater The dimension of each pipe part is G1 2 The massive pressure of inlet should use Pa as the unit The minimum pressure of inlet should use Pa as the unit Connection of pressu...

Page 7: ...essure release hole Pressure relief valve Cold water inlet Rubber seal gaskets Hot water outlet Cold water inlet Pressure relief valve Pressure release hole Joint screw for cold water inlet Adjusting...

Page 8: ...m the wall resulting in damage of the heater even serious accidents of injury When determining the locations of the bolt holes it shall be ensured that there is a clearance not less than 0 2m on the r...

Page 9: ...tat will automatically control the temperature When the water temperature inside the heater has reached the set temperature it will switch off automatically when the water temperature falls below the...

Page 10: ...be performed by special maintenance services You can ask the seller for address of the nearest service center 5 MAINTENANCE WARNING Do cut off power supply before maintenance to avoid danger like elec...

Page 11: ...act with the professional personnel for repair Contact with the professional personnel for repair No water coming out of the hot water outlet The water temperature is too high Water leak 1 The running...

Page 12: ...L kWh kWh L L Description Parameter Value Unit k Value k Smart control compliance smart Smart control factor SCF Conversion coefficient CC Ambient correction term Qcor Referenct energy Qref Useful en...

Page 13: ...tion Parameter Value Unit k Value k Smart control compliance smart Smart control factor SCF Conversion coefficient CC Ambient correction term Qcor Referenct energy Qref Useful energy content QH2O Corr...

Page 14: ...escription Parameter Value Unit k Value k Smart control compliance smart Smart control factor SCF Conversion coefficient CC Ambient correction term Qcor Referenct energy Qref Useful energy content QH2...

Page 15: ...of the average temperature p Volume that delivered water of at least 40 V40exp Calculated volume that delivered hot water of at least 40 V40 0 23 0 0 2 5 0 330 2 1 2 137 0 983 2 654 58 3 56 3 29 7 29...

Page 16: ...www midea com global The product is subject to change without notice Please keep this manual properly Midea Italia S r l A Socio Unico Viale Bodio 29 20158 Milano MI www midea com it...

Page 17: ...bili Prima di installare ed utilizzare il prodotto leggere questo manuale e conservarlo per le future necessit di consultazione Modello D10 15VDO D10 15VDU D15 15VDO D15 15VDU D30 15VDO D30 15VDU L im...

Page 18: ...allazione errata o dal mancato rispetto delle istruzioni incluse in questo libretto Per maggiori informazioni sulle condizioni di installazione e manutenzione dei prodotti fare riferimento a quanto se...

Page 19: ...i a persone o cose La pressione massima per l adduzione acqua pari a 0 5Mpa La pressione minima di adduzione acqua pari a 0 1Mpa Utilizzare gli adeguati accorgimenti per assicurare l erogazione di acq...

Page 20: ...a Leva Condotto di scarico D10 15VDO D10 15VDU Tensione nominale ACV 220 240 220 240 220 240 220 240 Modello IPX4 IPX4 75 65 65 75 1500 1500 Potenza nominale W 10 10 Volume L 0 8 0 8 0 8 0 8 0 8 0 8 P...

Page 21: ...Q Q Resistenza di riscaldamento Indicatore di riscaldamento Protettore termico Termostato Indicatore presenza rete Marrone Blu Giallo Verde Nota tutte le dimensioni sono espresse in mm D10 15VD D15 15...

Page 22: ...alore massimo e minimo espresso in Pa per il prodotto Collegare la valvola di sicurezza sul condotto di ingresso dell acqua fredda Utilizzare le guarnizioni di tenuta fornite con il prodotto per evita...

Page 23: ...acqua Scarico acqua Giunto T per acqua fredda Giunto T per acqua fredda Valvola di miscelazione Valvola di miscelazione Punto di prelievo Guarnizioni di tenuta Guarnizioni di tenuta Guarnizioni di te...

Page 24: ...ravi a cose e persone Durante la definizione della posizione di installazione mantenere uno spazio di rispetto libero da ostacoli pari ad almeno 20 cm dal lato destro del prodotto per garantire lo spa...

Page 25: ...spina nella presa Il termostato presente nel prodotto controlla la temperatura dell acqua Il riscaldatore elettrico viene avviato se la temperatura dell acqua inferiore al valore selezionato e si arre...

Page 26: ...guire operazioni di manutenzione per evitare il pericolo di scosse elettriche ATTENZIONE Lo scaldaacqua dotato di un protettore termico che interrompe l alimentazione elettrica al riscadatore elettric...

Page 27: ...Perdite di acqua Mancato controllo temperatura Problemi nei raccordi tra le varie componenti Realizzare correttamente i raccordi Il led di riscaldamento sempre spento Verificare l impostazione del ter...

Page 28: ...k smart SCF CC Qcor kWh Qref kWh QH2O kWh Qref QH2O kWh Qtest_elec kWh T3 T5 Mact kg Cact L Qelec kWh wh AEC kWh Descrizione Parametro Valore Unit Descrizione Parametro Valore Unit Tset p c p V40exp...

Page 29: ...ione Parametro Valore Unit Descrizione Parametro Valore Unit Tset p c p V40exp L V40 L k Valore Conformit controllo smart Fattore controllo smart Coefficiente di conversion Termine di correzione ambie...

Page 30: ...Qcor kWh Qref kWh QH2O kWh Qref QH2O kWh Qtest_elec kWh T3 T5 Mact kg Cact L Qelec kWh wh AEC kWh Descrizione Parametro Valore Unit Descrizione Parametro Valore Unit Tset p c p V40exp L V40 L k Valor...

Page 31: ...Qcor kWh Qref kWh QH2O kWh Qref QH2O kWh Qtest_elec kWh T3 T5 Mact kg Cact L Qelec kWh wh AEC kWh Descrizione Parametro Valore Unit Descrizione Parametro Valore Unit Tset p c p V40exp L V40 L k Valore...

Page 32: ...www midea com global Questo prodotto sar soggetto a cambiamenti senza preavvisi Conservare correttamente questo manuale Midea Italia S r l A Socio Unico Viale Bodio 29 20158 Milano MI www midea com it...

Reviews: