setting up the outdooR unit
Secure the outdoor unit with anchors using screws and nuts with a diameter of Ø 10 or Ø 8 mm horizontally on a stable
surface.
mounting the dRain plug
· Place the seal onto the drain plug and plug the drain plug into the bottom of the outdoor unit. Turn the plug by 90° to
secure it.
· Connect the drain plug to the extension of the condensation drainage hose if condensation has accumulated during
the "Heat" operating mode.
· Adhere to the floor clearance of 20 cm so that condensation can drain while heating in the winter and no icicles can
develop from the condensation dripping down, which will then reach into the appliance.
Air intake
Air intake
Air outlet
Model
A
(mm)
A
(mm)
≤ 16.000 BTU/h
458
250
≤ 16.000 BTU/h
530
290
A
B
Drain plug
Seal
installing coolant lines
Perform the installation for the outdoor air condi-
tioner as already described for the indoor unit.
caution
Never shorten the supplied copper pipes, even if they are too long. You can carefully
roll up the excess meters and store them behind the outdoor unit.