1. General display data 
     1

 General display data is displayed in all display pages.

                  

The icon      displayes when the centralized controller communicates with the

            computer or gateway normally, otherwise,  it does’t  display.
                  

The icon       displayes when the centralized controller communicates with the

            functional module normally,otherwise,  it does’t  display.     
                  

The icon       displayes when the centralized controller communicates with the

            the SMS remote control module normally, otherwise,  it does’t  display.
                  

The icon       displayes when the centralized controller communicates with the

           the telephone remote control normally, otherwise,  it does’t  display.     
                  

The icon       displayes in the cycle: (blank)

   

    

     

(blank),when the

           centralized controller communicates with the network interface normally.
                  

The icon “    ” displays as 0.5Hz when the current state is centralized controller 

           locking. The icon will be displayed constantly when the state is key locking. 
                  

The icon “     ”displays when the current state of the selected air conditioner

           is remote control locking.
                     The icon will always display if all the air conditioners are remote control locking.
                      In the global setting page,the icon displays if any air conditioner is remote 
           control locking. 
                  

The icon “     ” will be displayed, if the current state is cooling mode locking. 

                      The icon“      ” will be displayed, if the current state is heating mode locking.

     2

 Display data instruction

                  

Indoor unit code (address) display

Display range

:

00~63

with “#”  being 

            luminous concurrently.
                  

Indoor temperature display: Display range:00~99°C

 

(or 99°F). “°C” (or “°F”) 

            and “indoor temperature” are displayed concurrently. If the temperature is higher 
            than 99°C(or 99°F), 99°C(or 99°F) is displayed. If the temperature value is invalid, 
            “- -” is displayed.

 

                  

If timing startup/shutdown is set, the flag        is displayed.

                  

T3, T2A and T2B display: In the single-machine query page, display can shift 

            among “T3”, “T2A” and “T2B”, and the temperature value is displayed concurrently,
            with the corresponding “°C” (or “°F”) being luminous.
                  

In case of air conditioner fault or protection, the corresponding fault code or

            can be displayed. 
                  

Liquid crystal matrix display description:

2.4.2 LCD instruction

Installation & Owner‘s Manual 

19 

Summary of Contents for CCM30/BKE-A

Page 1: ...R S MANUAL Centralized Controller Thank you for purchasing our product Before using your unit please read this manual carefully and keep for future reference MODEL CCM30 BKE A CCM30 BKE B CE CCM30 BKE...

Page 2: ......

Page 3: ...peration part 8 2 1 Function instructions 9 2 2 Operation conditions 9 2 3 Key words 10 2 3 1 Status indication 10 2 3 2 Power on or reset 10 2 3 3 Emergency stop and forced on 10 2 3 4 Various lockin...

Page 4: ...INSTALLATION PART Installation Owner s Manual 1...

Page 5: ...me Remarks 3 core control shielded cable 2 PCS 1 PCS 1 PCS 2 3 PCS Several pieces 3 core cable Switch box Wire pipe jack casing pipe captive nut Tighten strip No No Quantity install into wall Selected...

Page 6: ...it with the terminal block 5 After the centralized controller is connected do not use megohmmeter to inspect the insulation of the signal cable 6 Wiring mode of the centralized controller and the netw...

Page 7: ...r 3 places Fix the screws of the centralized controller Base Front cover Address dial code Dial code Dial code position Address range Fig 1 2 Installation diagram Forced on switch Emergency stop switc...

Page 8: ...lized controller One computer can connect 16 centralized controllers at most A centralized controller can connect 64 indoor units at most A centralized controller can connect 64 indoor units at most A...

Page 9: ...may lead to personal injury or property loss Means improper handling may lead to personal death or severe injury Note Do not install the equipment in a place vulnerable to leakage of flammable gases O...

Page 10: ...itioner Both of the following wiring modes of centralized controller and indoor unit are applicable The number of indoor units connected with each centralized controller is not beyond 64 Indoor unit I...

Page 11: ...OPERATION PART Installation Owner s Manual 8...

Page 12: ...conditioner computer and centralized controller are applied to the master slave responding communication method In the LAN of centralized controller and air conditioner centralized controller will be...

Page 13: ...zer will buzz once If this key has long press function the centralized controller will carry on the relative functin but the buzzer will buzz once only When the backlight is off any key except for key...

Page 14: ...after centralized controller is re powered on or the is pressed The remote controller locking of the air conditioner is remained 2 Remote controller locking 1 Effect When the air conditioner is under...

Page 15: ...nd OFF operation for the air conditioners in the centralized controller network The ON mode will accord to the system mode locking or other limit conditions for judging if there is conflict it will au...

Page 16: ...memory contents and sends relative order to all air conditioners key long press a If current page is setting parameters and the setting mode is not OFF the central ized controller will send orders to...

Page 17: ...umns In the setting page press the OK key to send the setting information except the locking signal to the air conditioner In the setting page shift to the timing startup shutdown setting page press t...

Page 18: ...Time off key In setting operation mode press this key to set the timing shutdown of air conditioner Press the key again to exit the timing setting and restore the normal temperature regulation operati...

Page 19: ...y one 11 Upward key In the main page press this key to enter the query mode By default it is the first in service air conditioner In any other time press this key will select the previous correspondin...

Page 20: ...s follow 14 ON OFF key Any time when you press the key the centralized startup shutdown operation is performed for all current in service air conditioners in the centralized controller network Detaile...

Page 21: ...m e r u t a r e p m e T r e t e m a r a p n o i t c e l e s e d o M heating g n i l o o c o t u A r u o H g n i k c o l y e K r e l l o r t n o c e t o m e R g n i k c o l e d o m g n i t a e H g n i...

Page 22: ...air conditioner is remote control locking The icon will always display if all the air conditioners are remote control locking In the global setting page the icon displays if any air conditioner is rem...

Page 23: ...play description 1 Description of the main page Fig 2 5 The example diagram of the main page Installation Owner s Manual 20 The LCD displays the main page 60 air conditioners are in service which 28 a...

Page 24: ...00 and 00 01 are luminous It indicates the in service and power on status of the air conditioners with the addresses of 00 and 01 The centralized controller communicates with the computer normally 3 D...

Page 25: ...red on will be cleared Dial code 1 Dial code 2 Dial code 3 Dial code 1 Table 2 1 Dial code definitions Three pipe CCM30 Two pipe CCM30 Has optional function No optional function Installation Owner s M...

Page 26: ...2 3 After setting successfully Dual eight represented function selection and dual eight represented function selection will be lighted on the screen will display Setting successfully Fig 2 9 d After 3...

Page 27: ...Fault of communication between main board and display board Air speed detection out of control EEPROM error Zero crossing detection error Outdoor unit fault protection T2B sensor fault T2A sensor fau...

Page 28: ...2 5 Technical indices and requirements 1 EMC EMI comply with the CE certification requirements 2 Electrical safety comply with GB4706 32 2004 GB T7725 2004 Installation Owner s Manual 25...

Page 29: ...MD12IU 028BW 202055100922...

Page 30: ...1 18 2...

Reviews: