Service Manual_2018-V1.0
22
There is 2 light switch on the left side of freezer
room
1
)
Use slotted screwdriver pry up the light switch;
2
)
Disconnect the wiring connector.
Pilot light
None
Fresh light
None
8.4Air duct and fan motor
Air duct components of refrigerating chamber
All accessories in the refrigerating chamber
should be removed before dismantling the air duct
components.
1
)
Remove 4 fixed screw with a cross
screwdriver after removing the white
decorative cap on the surface of the air
duct;
2
)
Dismantle the supporting iron bar in the
middle of air duct cover of refrigerator room;
3
)
disconnect the wiring connector;