Service Manual_2018-V2.0
32
9.3 Sensor replacement
The sensor is located on the inner side of the upper
hinge cover and sends temperature signal to
microprocessor.
Defrost sensor in refrigerating chamber
The defrost sensor is located on top of the evaporator.
1
)
Disconnect the connector of defrost sensor
2
)
Cut off the band which fixes the sensor.
3
)
Separate the sensor and the evaporator.
Sensor replacement guidelines
Cut off the damaged head of sensor.
Strip off the sensor wiring.
Take out a new sensor to cut the head of sensor.
(Spare parts code
:
11201007000795) Its technical
specifications apply to all MIDEA refrigerators.
Summary of Contents for 22031020003641
Page 5: ...Service Manual_2018 V2 0 5 1 Significant update notes None...
Page 18: ...Service Manual_2018 V2 0 18 6 5Main control board schematic diagram...
Page 20: ...Service Manual_2018 V2 0 20 7 3 Circulating route of cooling air...
Page 38: ...Service Manual_2018 V2 0 38 12 Troubleshooting Method 12 1 No cooling Air cooling Electronic...
Page 39: ...Service Manual_2018 V2 0 39 12 2 No working of compressor 12 3 Inside frosting no defrosting...
Page 40: ...Service Manual_2018 V2 0 40 12 4 Inside frosting no defrosting Maintenance guidelines...
Page 41: ...Service Manual_2018 V2 0 41 12 5 Light is not on 12 6 Fan failure...
Page 42: ...Service Manual_2018 V2 0 42 12 7 Defective defrost circuit 12 8 Noise...
Page 43: ...Service Manual_2018 V2 0 43 12 9 Air duct not operated electronically None...
Page 44: ...Service Manual_2018 V2 0 44 13 Figures and details of repair parts See this section in the TSP...