Service Manual
, 2016-12
24
/
47
❶
Fuse
The fuse is located on top of the evaporator
1
)
connect the fuse connector.
2
)
Cut off the band which fixes the fuse.
3
)
Separate the fuse and the evaporator.
*Don’t break the welding of the evaporator in case that
only the sensor needs to be replaced.
❷
Defrost sensor
The defrost sensor is located on top of the evaporator.
1
)
Disconnect the connector of defrost sensor
2
)
Cut off the band which fixes the sensor.
3
)
Separate the sensor and the evaporator.
*Don’t break the welding of the evaporator in case that
only the sensor needs to be replaced.
❸
Defrost heater
The defrost heater is located at bottom of the evaporator.
1
)
Disconnect the connector of defrost heater.
2
)
Cut off the band which fixes the defrost heater.
3
)
Take off the defrost heater from the evaporator.
*,Dont break the welding of the evaporator in case that
only the defrost heater needs to be replaced.
Ambient temperature sensor
None
Ambient temperature sensor
Ambient temperature sensor is located in upper hinge
cover,