background image

INSTALLATION & OPERATION MANUAL 10305 REV 1 (08/22)

 PAGE

7    

OF20

Self-Generating Steam Jacketed Counter Tilting Kettle

O

peration

O

PERATION

Operating

 I

nstructions

1.  Ensure that the external electrical shut-off to the kettle is on.

2.  Check pressure gauge for correct cold kettle reading. Reading should be in the green vacuum zone. If reading is not 

in the vacuum zone, follow VENTING INSTRUCTION prior to using the kettle.  

3.  Place power switch in ON position.

4.  Preheat the kettle by placing thermostat knob at maximum and wait until TEMPERATURE light goes off.

 

NOTICE

Preheating should not be used when cooking milk and egg food products which adhere to hot cooking surfaces. 

These foods should be placed into kettle before heating is begun.

5.  Add food to be cooked into the kettle.
6.  Place thermostat knob at required temperature setting with a temperature range from roughly 165 °F to 289 °F 

(74 °C to 143 °C, jacket temperature.)

7.  When cooking is finished set thermostat knob and power switch to the OFF position.
8.  Pour finished product from kettle using tilt handle. Be careful to avoid splashing.

9.  Add water to kettle for cleaning purposes.
10. Wash kettle thoroughly. See CLEANING procedure.

T

ilting

 I

nstructions

Your kettle has the standard “Clean Lock” feature and may not be tilted without disengaging the tilt knob located 

on the console at the top right. This feature locks the kettle in the upright position and also allows the operator 

to lock the kettle at 105 degrees for ease of cleaning. To tilt the kettle the full distance, the tilt lock knob must 

be disengaged from the cleaning position by pulling out the tilt lock knob and tilting the kettle forward the full 

distance. Follow these steps to tilt kettle:
1.  Pull out the tilt knob near top right of console.
2.  Using kettle tilt handle pull kettle forward to desired angle of pour or until kettle locks at 105 degrees. The tilt 

knob can be released after the kettle has been tilted approximately 10°.

3.  Kettle will lock in position at 105 degrees and may be tilted further by pulling the tilt lock knob a second time 

allowing the kettle to tilt the full distance.

4.  To return the kettle to the upright position, pull out the tilt lock knob and tilt the kettle upward until it locks in 

the upright position. The kettle should not move in either direction once in the upright position.

Summary of Contents for CROWN EC-10TW-L

Page 1: ...___ WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before...

Page 2: ...ions IMPORTANT NOTES FOR INSTALLATION AND OPERATION NOTICE Contact the factory the factory representative or local service company to perform maintenance and repairs It is recommended that this manual...

Page 3: ...enerating Steam Jacketed Counter Tilting Kettle RETAIN THIS MANUAL FOR FUTURE REFERENCE Table of Contents Safety 2 Service Connections 4 Introduction 5 Installation 6 Operation 7 Cleaning 8 Troublesho...

Page 4: ...15 25 387 22 25 565 4 50 114 27 686 4 25 108 12 38 314 10 254 EC 10TW L 10 gallons 38 liters in mm 16 406 15 381 26 660 34 88 886 17 25 438 26 25 667 4 62 117 28 711 6 12 156 14 75 375 12 75 324 EC 1...

Page 5: ...1 Operator turns the power switch to the ON position and sets the temperature control dial to the desired temperature setting 2 Control circuit is normally completed to the temperature controller if...

Page 6: ...ve appliance from counter and locate position of 4 holes as per Figure 1 Drill four 7 16 diameter holes 5 Apply a continuous bead of Silastic or other equivalent sealant along the complete perimeter e...

Page 7: ...ul to avoid splashing 9 Add water to kettle for cleaning purposes 10 Wash kettle thoroughly See CLEANING procedure Tilting Instructions Your kettle has the standard Clean Lock feature and may not be t...

Page 8: ...e under any condition Failure to comply will void warranty NOTICE Never scrape the inside of the kettle with metal tools steel scouring pads or abrasive cleaners Scratches will result which will spoil...

Page 9: ...le to operate Depletion of water may occur from excessive opening of or leakage through the safety relief valve If water is below required operating level either initially at start up or during use th...

Page 10: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 10 OF 20 Self Generating Steam Jacketed Counter Tilting Kettle Appendix A Material Safety Data Sheets...

Page 11: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 11 OF20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 12: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 12 OF 20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 13: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 13 OF20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 14: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 14 OF 20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 15: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 15 OF20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 16: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 16 OF 20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 17: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 17 OF20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 18: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 18 OF 20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 19: ...INSTALLATION OPERATION MANUAL 10305 REV 1 08 22 PAGE 19 OF20 Self Generating Steam Jacketed Counter Tilting Kettle Material Safety Data Sheets...

Page 20: ...intenance We all recognize however that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Crown Author...