UTILITY ROUGH-IN DIMENSIONS AND POSITIONING
FOR PS629E-SERIES OVEN
WARNING
Do not use conduit for ground connection.
CAUTION
It is recommended that the oven be placed
under a ventilation hood for adequate air supply
and ventilation.
IMPORTANT
Electric supply to be provided by customer.
CIRCUIT BREAKER
Separate circuit breaker with lockout/tagout electrical
shutoff for each oven. Wire each oven separately.
60 Amp circuit breaker for 208-240V 1ph, 50 Amp
circuit breaker for 208-240V 3ph, or 30 Amp circuit
breaker for 380-480V.
ELECTRICAL SPECIFICATIONS
Blower/
Element
208V 240V 380V 280V 230V 240V
Phase 3 3 3 1 1 1
Circuit
208/
240
208/
240
208/
240
208/
240
208/
240
208/
240
kW 12 12 12 10 9.2 10
Frequency 50/60 50/60 50/60 50/60 50/60 50/60
Poles 3 4 4 2 2 2
Wires 4 5 5 3 3 2
L1
35.3 30.8 20.2 48.1 40.0 41.7
L2
35.3 30.8 18.2 48.1 40.0 41.7
L3 33.3
28.8
18.2 - - -
N - - 2.0 - - -
SUPPLY WIRE
Supply wire size must be in accordance with the
National Electrical Code (current edition) and must be
in compliance with local codes.
SUGGESTED
If space permits, service should be located near the
control console end of the oven(s) to allow convenient
access to safety switches.
Typical PS629E-Series Oven(s)
Installation
NOTICE
Where national or local codes require the installation
of fire suppression equipment or other supplementary
equipment, DO NOT mount the equipment directly to
the oven.
Mounting such equipment may:
•
Void agency certifications
•
Restrict
service
access
•
Lead to increased service expenses for the owner
NOTICE
Unit must have plate air vents installed or warranty
will be void.
II. VENTILATION GUIDELINES
A mechanically driven ventilation system is
recommended for the PS629E Series Middleby
Marshall conveyorized electric ovens.
Local codes and conditions vary greatly from one area
to another and must be complied with. Following are
the suggested requirements for good ventilation.
Please remember these are recommendations or
guidelines, you may have a special condition or
problem that will require the services of a ventilation
engineer or specialist. Proper ventilation is the oven
Summary of Contents for PS629E Series
Page 10: ...SECTION 1 DESCRIPTION 10 NOTES...
Page 18: ...SECTION 3 OPERATION 18 Model PS629E Dimensions with Optional Legs Casters...
Page 22: ...SECTION 3 OPERATION 22 NOTES...
Page 30: ...SECTION 3 OPERATION 30 NOTES...
Page 37: ...SECTION 4 MAINTENANCE 37...
Page 44: ...SECTION 4 MAINTENANCE 44...
Page 48: ...SECTION 5 TROUBLESHOOTING 48 Wiring Diagram E230V 1PH CE PS629E 74665 REV F...
Page 49: ...SECTION 6 ELECTRICAL SCHEMATICS 49 Wiring Diagram E380V 3PH PS629E 74667 REV F...
Page 50: ...SECTION 5 TROUBLESHOOTING 50 Wiring Diagram E380V 3PH CE PS629E 74669 REV F...