4
SECTION 1
DESCRIPTION
II. COMPONENT FUNCTION (Figure 1-4)
II. COMPONENT FUNCTION
A. Conveyor Motor and Conveyor Belt
The conveyor belt is driven by a variable-speed electric
motor (Figure 1-5) operating through a gear reducer.
The motor speed is controlled by a digital control. The
stainless-steel wire belt can travel in either direction at
variable rates ranging from 30 seconds to 12 minutes; this
is the time that a product can take to pass through
the oven.
B. Blower Fan
The circulation air blower drive motors (2) are located in
the right side control box. The blowers force heated air
through the air fingers. The MAIN / BLOWER switch
must be set to “ON” or “I” for oven warmup and baking.
C. Cooling Fan — See Figure 1-5 and Figure 1-6
Cooling fans are located at the rear of each (left and
right) control box. Cooling air is drawn into each control
box and blown across the control components and
circulating blower bearings and exits the oven front and
rear louvers.
IMPORTANT
THE CONTROL BOX DOORS MUST BE
CLOSED WHILE THE OVEN IS HOT OR
H E A T I N G I N O R D E R T O K E E P T H E
COMPONENTS AND BEARINGS COOL.
D. Air Fingers - See Figure 1-7
An Air Finger Assembly is made up of three parts:
1.
Outer Plate -
The Outer Plate is the removable covering
with tapered holes, which direct the air stream onto the
product being baked.
2.
Inner Plate
-The perforated Inner Plate is vital in forming
the unique air jets. It must be assembled into the manifold
with its holes aligned with the holes of the outer plate.
3.
Manifold -
The Manifold is the assembly which slides
on tracks into the oven plenum.
Figure 1-5. Machinery Compartment
Components
Blower Assembly
Right Control Box
#OOLING&AN
"LOWER
-OTOR
Conveyor
Drive Motor
Summary of Contents for PS624E
Page 14: ...10 SECTION 2 INSTALLATION Figure 2 5 MODEL PS624 SINGLE OVEN DIMENSIONS...
Page 15: ...SECTION 2 INSTALLATION 11 Figure 2 6 MODEL PS624 DOUBLE OVEN DIMENSIONS...
Page 16: ...12 SECTION 2 INSTALLATION Figure 2 7 MODEL PS624 TRIPLE OVEN DIMENSIONS...
Page 23: ...SECTION 3 OPERATION 19 Figure 3 6 Control Panel 4 6 9 2...
Page 40: ...36 SECTION 4 MAINTENANCE NOTES...
Page 42: ...SECTION 5 TROUBLESHOOTING 38 NOTES...
Page 44: ...SECTION 6 ELECTRICAL SCHEMATICS 40 Wiring Diagram E380V 17 44 kW PS624E PS824E 61577B...
Page 45: ...41 SECTION 6 ELECTRICAL SCHEMATICS Wiring Diagram E380V 17 4 kW PS624E PS824E CE 61581B...
Page 46: ...SECTION 6 ELECTRICAL SCHEMATICS 42 Wiring Diagram 400 416V 4 kW PS624E PS824E 61534B...