background image

MIDAS TOUCH INC 

45 

MAC-1000PEF/PMF Hardware Manual 

 

4.2.3.5  Set Read Interface 

 

Allow the users to select read interface. 0 is T1/T2 reader interface. 1 is Wiegand 26(8) 

(system will retrieve 8 digits). 2 is Wiegand 26(10)(system will read 8 digits back and add 

00 automatic in front of number. Total will retrieve 10 digits.) 3 is Wiegand 34 (system will 

retrieve 10 digits). 

 

Operation Instruction: 

 

 

 

 

 

 

 

 

Master Card/Code 

(Default 30191000) 

Sys Setup 

Read Interface 

0=T1/T2 

1=Wiegand 26(8) 

2=Wiegand 26(10) 

3=Wiegand 34(10) 

Completed 

Completed 

Completed 

Completed 

Summary of Contents for MAC-1000

Page 1: ...MIDAS TOUCH INC 1 MAC 1000PEF PMF Hardware Manual MAC 1000 Standalone Fingerprint Access Controller Hardware Manual Version 1 3 2...

Page 2: ...e Connection 15 3 2 3 2 NC Mode Connection 16 3 2 3 3 Magnetic Door Lock Connection 16 3 2 4 Exit Button Door Sensor Connection 17 3 2 5 Siren Alarm Connection 17 3 2 6 Communication Interface Connect...

Page 3: ...Date 41 4 2 3 2 Set Time 42 4 2 3 3 Set Date Format 43 4 2 3 4 Set Keypad Status 44 4 2 3 5 Set Read Interface 45 4 2 3 6 System Initiation 46 4 2 4 Comm 47 4 2 4 1 Set Communication Way 47 4 2 4 2 Se...

Page 4: ...ion V1 0 First Edition V1 1 Modify case sensor V1 2 Modify 1 2Features 1 3 Specification and Add the Installation F Tear off the protective film V1 3 Modify the wire connections DC 12V IN and SGND V1...

Page 5: ...MIDAS TOUCH INC 5 MAC 1000PEF PMF Hardware Manual Chapter 1 Product Overview 1 1 Package Contents Controller x 1 Quick Start Guide x 1 Plate x1 Hex Key Wrench x 1 Screw x 4 Cable x 2...

Page 6: ...500 fingerprint templates Quick and accurate fingerprint verification supports 1 1 authentication 1 N identification And audible voice prompts guiding users during verification process Provide 32 work...

Page 7: ...tification Mode 1 1 1 N Identification Time 1 1 1 second 1 1 000 1 second FAR FRR 0 001 0 01 Fingerprint Sensor Optical CMOS Sensor LED Indicator Power Comm LCD Display 128 x 64 Dot Graphic Display wi...

Page 8: ...MIDAS TOUCH INC 8 MAC 1000PEF PMF Hardware Manual Chapter 2 Physical Dimension 2 1 Dimension Scale mm 2 2 Appearance Introduction...

Page 9: ...ed indicates successful transmission Flashing red led only indicates no response of controller Bell Bell Function key Request Bell function should select mode 1 and activate by HAMS Relay Active as be...

Page 10: ...act CN1 Connector for Power Exit Button Lock Sensor Relay etc Kindly refer to follow figure Relay3 Reserved Case Sensor Reader tamper proof detection Comm Switch TCP IP or RS 485 Switch up is TCP IP s...

Page 11: ...MIDAS TOUCH INC 11 MAC 1000PEF PMF Hardware Manual...

Page 12: ...MIDAS TOUCH INC 12 MAC 1000PEF PMF Hardware Manual Chapter 3 System Configuration Wire Connections 3 1 System Configuration...

Page 13: ...for set communication way and NODE ID A Mount the fixed iron plate onto the wall with screws B Connect the wires in accordance with the wiring instruction CN1 CN2 C D Install the controller upper cov...

Page 14: ...ACU 30 Wire Diagram Relay Active as below Relay 0 signifies Controller relay Relay 1 2 signifies relay in the external relay board Relay0 Relay1 Relay2 Mode 0 Default Door Door Siren Alarm Mode 1 Bell...

Page 15: ...00PEF PMF Hardware Manual 3 2 3 Electronic Lock Setup Wiring of using built in relay 3 2 3 1 NO Mode Connection This wire connection is mode 0 This is doo bell connection of mode 1 Will activate bell...

Page 16: ...MIDAS TOUCH INC 16 MAC 1000PEF PMF Hardware Manual 3 2 3 2 NC Mode Connection This wire connection is mode 0 3 2 3 3 Magnetic Door Lock Connection This wire connection is mode 0...

Page 17: ...MIDAS TOUCH INC 17 MAC 1000PEF PMF Hardware Manual 3 2 4 Exit Button Door Sensor Connection 3 2 5 Siren Alarm Connection Siren Alarm wiring is same in Mode 0 and Mode 1...

Page 18: ...TOUCH INC 18 MAC 1000PEF PMF Hardware Manual 3 2 6 Communication Interface Connection NOTE To avoid device damage please do not connect it with PoE Hub 3 2 6 1 RS 485 Connection 3 2 6 2 TCP IP Connec...

Page 19: ...ader Connection PXR 82MFS only support MAC 1000PMF T1 T2 W26 W34 Reader Connection If the slave reader is wiegand format the wire distance should be within 30M Slave reader and DVR are using same cont...

Page 20: ...S TOUCH INC 20 MAC 1000PEF PMF Hardware Manual 3 2 8 Power Supply Connection Note To avoid interference self detection of sensitive keypad please do not touch keypad when input power 3 2 9 DVR Connect...

Page 21: ...anual Chapter 4 Setting 4 1 RS 485 TCP IP Selection to PC Please select RS 485 or TCP IP communication way Note Follow SW2 DIP switch setting should identical with command 70 then the communication wi...

Page 22: ...en you will into menus operation Function key F1 and F2 are for function selections When you select the functions the item which you selected will be marked When you press function key it will access...

Page 23: ...EF PMF Hardware Manual 4 2 1 Card Manage 4 2 1 1 Add Fingerprint Allows to select restricted or unrestricted of time schedule for user The card number must be pure 10 digits of MAC 1000PEF PMF Operati...

Page 24: ...finger if scan failed system will return to upper menu If enroll first finger success but second finger failed system will also return to upper menu and anew the enroll process Card Manage Enro Unrest...

Page 25: ...only select a time zone Card Manage Card No If do not need password press function key to skip this step If do not need password press function key to skip this step Password Access by card swiped fin...

Page 26: ...1 2 Delete Fingerprint Deletes a single user or all users fingerprint templates and also removes its access authorization Operation Instruction Delete A Single User Master Card Code Default 30191000...

Page 27: ...MIDAS TOUCH INC 27 MAC 1000PEF PMF Hardware Manual Delete All Users Master Card Code Default 30191000 Card Manage Del FP_Card Del All Card 1 Yes 0 No Del Success Del All Card...

Page 28: ...e Manual 4 2 1 3 Change Fingerprint Allow user to change fingerprint template Operation Instruction Master Card Code Default 30191000 Card Manage C_Card FP Card No 1 Examine Finger 1 Examine Finger 2...

Page 29: ...ation Instruction Continue Master Card Code Default 30191000 Card Manage Change Sch Card No Screen will display original time schedule Please input new time Schedule 255 means open 24 hours Continue t...

Page 30: ...ns below and input max length is 13 digits for master code Whenever a device initiation has been performed master code will be restored back to default 30191000 Operation Instruction Change master cod...

Page 31: ...as master card the original master card will become invalid card To resume master card function please delete the master fingerprint Master fingerprint has priority in the system Master Code Card Defa...

Page 32: ...MF Hardware Manual Delete master fingerprint Note After delete master fingerprint if master card has been set before user may swipe card or press keypad into menu Master fingerprint Card Manage Master...

Page 33: ...llow the instructions below and input maximum length is 13 digits for disarm card code Whenever a device initiation has been performed disarm code will be restored back to default 0000 Operation Instr...

Page 34: ...llow the instructions below and input maximum length is 13 digits for duress card code Whenever a device initiation has been performed duress code will be restored back to default 1190 Operation Instr...

Page 35: ...0 00 00 00 signifies whole day close 00 00 23 59 signifies whole day open Operation Instruction Master Card Code Default 30191000 Access Info Completed Input Time Zone No Default Time Zone No 000 sign...

Page 36: ...et time zone first Kindly refer to Chapter 4 2 2 1 Time Zone Operation Instruction Master Card Code Default 30191000 Access Info Completed Input Time Schedule No Default Time Schedule No 000 signifies...

Page 37: ...e sets 255 then the function is deactivated Please set time zone and time schedule first Kindly refer to Chapter 4 2 2 1 and Chapter 4 2 2 2 Operation Instruction Master Card Code Default 30191000 Acc...

Page 38: ...is 4 seconds Time duration can be set from 0 1 409 5 seconds If parameter sets to 0 or greater than 409 5 seconds the parameter is ineffective Operation Instruction Master Card Code Default 30191000...

Page 39: ...e has been entered Toggle Mode It will change the relay condition after ever time being activated For example relay on become to relay off Pulse Mode it will return to original position within the tim...

Page 40: ...ction time has been set system will monitor door s status If the allotted door open time has expired and door does not close controller will make beep sound continuity until the door has to be closed...

Page 41: ...mm dd w yy stands for year 00 99 mm stands for month 01 12 dd stands for date 01 31 and w stands for week 1 7 Operation Instruction Master Card Code Default 30191000 Sys Setup Screen displays origina...

Page 42: ...e format is hh mm ss hh represents hours 00 23 mm for minutes 00 59 and ss for seconds 00 59 Operation Instruction Master Card Code Default 30191000 Sys Setup Screen displays original time For Example...

Page 43: ...M DD Input 1 date format is MM DD YYYY Input 2 date format is DD MM YYYY YYYY is year MM is month DD is date Operation Instruction Master Card Code Default 30191000 Sys Setup Date Format Default value...

Page 44: ...fore disable keypad function please set a new Master Card first hence disabling the keypads will lock you out of the command prompt 2 If input master code by swiped card please does not set Retrieve V...

Page 45: ...em will retrieve 8 digits 2 is Wiegand 26 10 system will read 8 digits back and add 00 automatic in front of number Total will retrieve 10 digits 3 is Wiegand 34 system will retrieve 10 digits Operati...

Page 46: ...ber and parameter should be reset Initiation should be performed only when the following occurs 1 On the initial installation set the MAC 1000 parameter to its default settings before deployment 2 If...

Page 47: ...y of controller The parameter 0 signifies TCP IP 1 signifies RS 485 This setting should identical with Chapter 3 2 6 and Chapter 4 1 Operation Instruction Press function key to exit the menu or wait f...

Page 48: ...roller s IP address Default IP address is 172 016 250 100 The communication way must select TCP IP otherwise the setting is ineffective Operation Instruction Master Card Code Default 30191000 Comm Scr...

Page 49: ...Controller s submask Default value is 255 255 0 0 The communication way must select TCP IP otherwise the setting is ineffective Operation Instruction Master Card Code Default 30191000 Comm Screen wil...

Page 50: ...anual 4 2 4 4 Set Gateway Set controller s gateway Default value is 000 000 000 000 The communication way must select TCP IP otherwise the setting is ineffective Operation Instruction Master Card Code...

Page 51: ...Port Set controller s port Default value is 4660 The communication way must select TCP IP otherwise the setting is ineffective Operation Instruction Master Card Code Default 30191000 Comm Port Screen...

Page 52: ...1 19200 2 38400 3 115200 The communication way must select RS 485 otherwise the setting is ineffective Operation Instruction Master Card Code Default 30191000 Comm Default value is 19200 Program will...

Page 53: ...al 4 2 4 7 Set Node ID Set controller s ID ID range from 001 255 The communication way must select RS 485 otherwise the setting is ineffective Operation Instruction Master Card Code Default 30191000 C...

Page 54: ...ction Allow user to select language 0 English 1 Traditional Chinese 2 Simplified Chinese Operation Instruction Master Card Code Default 30191000 Language Default is English Program will mark current s...

Page 55: ...llow Version XXX Communication Way TCP IP or RS 485 Node ID XXX Baud Rate XXXXXXBPS IP XXX XXX XXX XXX Submask XXX XXX XXX XXX Gateway XXX XXX XXX XXX Port XXXX Card XXXXX Event XXXXX Operation Instru...

Page 56: ...t password then press If password is unnecessary please press 7 Add two different fingerprint templates 8 Upon successful addition system will request to add another new card number For adding more ca...

Page 57: ...r does not open The electronic lock disconnection or bad connection And check whether the lock is properly installed Kindly refer to Chapter 3 2 3 Electronic Lock setup Controller doesn t communicatio...

Page 58: ...rization through HAMS Kindly refer to manual Set alarm t ime but alarm does not activate 1 Alarm wire disconnection 2 Bad Alarm 3 The Alarm timetable doesn t download to controller Or Alarm relay sett...

Page 59: ...e This program used broadcast search and connection method And the terminal s firewall should be shut down in order to locate the devices B Workspace Description Device List Found devices are listed i...

Page 60: ...devices connected over the network New settings area Modifies device s IP address Submask Gateway Port and Baud Rate Broadcast Setup This button will set new parameters to a device via broadcast meth...

Page 61: ...OUCH INC 61 MAC 1000PEF PMF Hardware Manual ID C 4 Select a device as shown below C 5 Current settings of the selected device will be displayed in the New settings area To modify it overwrite the para...

Page 62: ...n about the network environment from your IT personnel All parameter settings should be the same with the system in order to establish connection with the devices C 6 Verify the new parameters before...

Page 63: ...nual C 7 Upon completion of the settings the device will automatically restart and temporarily disconnects from the network Kindly wait for 10 20 sec before searching the device again Check if the par...

Page 64: ...4 core shielded twisted pair wire 20 22 AWG 25M RS 485 Cable 4 core shielded twisted pair wire 20 22 AWG 800 M Upgrade the cable specification according to transmission distance Upgrade the cable spe...

Page 65: ...peration or maintenance connection to improper equipment or attempted repair by anyone other than In no event shall manufacturer s liability exceed the price paid for the product from direct indirect...

Reviews: