Receiver Screens
Operating Controls
3-2
CodeRunner 4 Operator’s Guide
400438-1
Rev. J
3.2.1
Main Screen
The Main Screen appears when the receiver is powered up. It contains the following display
options:
•
Message Bar – display current software as a default. If a system error occurs, the
Message Bar displays diagnostic or error messages. For interpreting diagnostic
messages, see
Section 4,
Troubleshooting
on page 4-1
.
•
Displays Receive Frequency and Receive Signal Level (RSL).
•
Channel Plan Bandwidth (12 MHz or 17 MHz)
•
Local or Remote Control Mode
•
IF Bandwidth:
– NRM – Normal
– NRW – Narrow
– WDE – Wide
•
Change the following setting from the Main Screen:
– IF Bandwidth
– Band – 2, 7, or 13 GHz
– Channel – 1-10 (2 GHz), 1-14 (7 GHz), or 1-22 (13 GHz)
– Offset: 0, –, + or ++ (++ Offset applicable to 13 GHz band only)
Figure 3-2
Main Screen
Note:
When any operating fault is detected, the fault message is displayed
in place of the “Software Release.”
CodeRunner.4 Rel. 2.00
1995.750MHz
RSL-89.2dBm
Band:2
17MHz
Chnl:1
BW:NRM
LOCAL
Offset:–
Menu
DIGITAL
REMOTE
POWER
SQUELCH
ALARM
Receive mode: “DIGITAL” or “ANALOG“
Channel Plan (12MHz or 17MHz)
“LOCAL” or “REMOTE”
Receive Signal Level
Message Bar:
Bandwidth: “NRM” (Normal)
“NRW” (Narrow)
“WDE” (Wide)
Channel
Band
Frequency
Normal display of Software Release
or Fault Message (
See Note
)
Channel Offset
To Menu Screen