Wizard-style action in SNMP is achieved by setting a MIB object
“ccmSDIDULinkCfgMode”. If this MIB object is enabled then the entire Link
configuration will be updated into the temporary wizard section. After the full
configuration, the “ccmSDIDURadioLinkReconfigure” MIB object needs to be set
to reflect the changes made.
A detailed procedure for link configuration through SNMP is listed below
1. SET the ODU Opmode by setting the “ccmSDIDULinkCfgODUOpMode”
MIB object.
2. GET the IDU opmode list by reading the MIB
“ccmSDIDULinkUtilIDUEastOpmodeList”. “List” will give the list of possible
op modes. Select a number corresponding to the required opmode.
3. SET IDU op-mode by setting the number selected above in to MIB object
“ccmSDIDULinkEastOpModeIndex”
4. GET the “ccmSDIDULinkUtilEastODUChList” MIB variables value
5. SET the channel number gotten above in to the
“ccmSDIDURadioEastODUCfgChFreq”.
6. Update the configurations done so far using
“ccmSDIDURadioLinkReconfigure”
7. The selected configuration row index can be viewed by reading the MIB
“ccmSDIDULinkUtilEastChRowIndex”
3.3.33 ODU Power
User Access Level: Level 2
Figure 3-41. ODU Power
3.3.33.1 Description
The screen shown in Figure 3-41 enables the user to configure the ODU power.
The following parameters are displayed