Maintenance 

 

1. No action after turn on the machine

 

1). Check the plug as to whether it connects well enough to the wall socket or whether it is 

broken.  

2). Check the power switch or the digital controller whether it is broken. 

3). Check the fuse whether it has been burnt out. 

4). If the indicating light is on, but there is no visible display on screen, check the 5 cables of the 

Railway transformer. If 

it’s loose this shows the problem is the result of a poor connection. If it 

connects well, this could be the transformer is faulty.  

2. The display screen is working well, but the temperature is not increasing on the mug 

heater.

 

1). Check whether the thermocouple of the mug heater is connected well. If the thermocouple is 

loose, the display will show 255

 

and also results in the machine beeping. 

2). Check if the indicating light of solid-state relay is on, if not, check if the relay or digital 

controller is broken.  

3). If you already changed the new solid-

state relay but the mug heater still can’t heat up, 

check if the mug heater is faulty 

or the mug heater’s power cable is loose, if it is faulty a 

replacement mug heater will be required. 

3. The display screen shows 255

 

once you power on.

 

1). Check whether the thermocouple connection is loose or not. 

2). If the thermocouple is connected well, but still shows a temperature of 255

, then it is faulty. 

4. The machine is heating during 0~180

, but display number jumps to above 200

 

or 

300

 

suddenly, or the numbers on display jumps irregularly.

 

1). Check whether the thermocouple of the mug heater is connected well. 

2). If the thermocouple is connected, it shows that the program of the digital controller is broken. 

A replacement controller will be required.  

5. The temperature is out of control: Set temperature is 180

but the actual temperature 

is above 200

 

1). This means the solid-state relay is broken, when the temperature is out of control, the relay 

will need to be replaced.  

2). Or the digital controller is faulty and it keeps conveying electric to the relay, a replacement 

controller will be required. 

6. The setting temp and time becomes abnormal after exchange the mug heater.

 

1). Please reset the temp and time referring to the operation process manual. 

7. Other notices

 

1). In order to prolong the machine service life, please add the lubrication oil regularly to the 

joints. 

2). In order to keep the mug heaters transfer effect, please protect it carefully whenever you are 

using or not. 

3). Please store the machine in a dry place. 

Summary of Contents for MP-60

Page 1: ...Microtech User Manual 2018 Page 1 of 6 Digital Mug Heat Press Manual Model No Model No MP 60 Contents 1 Assembly Drawing 2 2 Technical Parameters 2 3 Operating Process 3 ...

Page 2: ...inting Methods 4 4 Recommendations 4 5 Maintenance 5 6 Circuit Diagram 6 1 Assembly Drawing 1 GY 04 Digital Controller 2 Power Socket 3 Power Switch 4 Handle toggle 5 Pressure Adjustment Screw 6 M5 Screw 7 Mug heater 8 Machine Feet 2 Technical Parameters MP 60 Technical Parameters Model No MP 60 ...

Page 3: ... on the machine via the power switch the temperature light will be ON The digital display will show the following on the LCD Press the OK button this will enable you to select a temperature reading C denotes Celsius Press arrows or to select or F denotes Fahrenheit according to your habits Press button to confirm your desired temperature reading the temp light will now display Select with arrows t...

Page 4: ...t to 20 and then press the OK button 5 seconds return to operation mode The temperature readings should now be accurate with the heat platen 3 Printing Methods Step 1 Make sure the cord is connected well to the wall socket Place the mug in the mug heater tape the transfer paper with the printed images facing down on the mug adjust the press to apply moderate pressure and power on P S please use he...

Page 5: ... heater will be required 3 The display screen shows 255 once you power on 1 Check whether the thermocouple connection is loose or not 2 If the thermocouple is connected well but still shows a temperature of 255 then it is faulty 4 The machine is heating during 0 180 but display number jumps to above 200 or 300 suddenly or the numbers on display jumps irregularly 1 Check whether the thermocouple of...

Page 6: ...ge this for a a new one after doing transfer prints for roughly 700 cycles If you use our Grade A mug heater then you may change the mug heater after 2000 transfer cycles 5 If you are not able to solve the electrical parts problem please kindly contact the supplier and get technical support 6 Circuit Diagram ...

Reviews: