background image

 

migan Ethernet IP

 

Large Format Numeric LED Display with Ethernet IP Interface

 

 

Page 19 

microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach 

 +49 9681 91960-0, 

 +49 9681 91960-10, [email protected], www.microsyst.de 

 

 

 

 
 

4.7  Versions Overview 

 

 

Version  Date 

Remarks, Description 

 

1.00 
1.10 

 
 
 

 
18.07.16 
20.11.17 

 
Document created  
Change of address 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Certified per 

DIN EN ISO 9001

 

Summary of Contents for migan

Page 1: ...electronic GmbH Am Gewerbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de migan Ethernet IP Large Format Numeric LED Display with Ethernet IP Inter...

Page 2: ...GENERAL 3 2 TECHNICAL INFORMATION 3 2 1 Device Configuration 4 2 2 Connector Pin Assignments 5 2 3 Device Start 6 2 4 Ethernet IP Configuration 7 3 CONTROL DATA 8 3 1 Control Frame Display Output 8 3...

Page 3: ...segment LED Character heights Indoor use 60 100 150 200 250 mm Outdoor use 100 200 300 mm Number of digits 1 40 Number of lines Standard 1 line multiple lines on request Display colour Standard red ot...

Page 4: ...mm 250 mm 300 mm Number of lines ________ Number of digits per line ________ Display colour red green yellow white blue View single sided double sided ____ sided Operating voltage 230 VAC 50 Hz 110 VA...

Page 5: ...bach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 2 2 Connector Pin Assignments Please see inside labelling of the mating plugs for pin assignment Power Connector 230 VAC Power...

Page 6: ...681 91960 0 49 9681 91960 10 info microsyst de www microsyst de Ethernet Socket 2 3 Device Start Following things are displayed after power up Segment test first 2 digits of the baud rate parity data...

Page 7: ...com in the area SUPPORT Anybus Communi cator Ethernet Serial Gateway Connect the display with a RS232 null modem cable pins 2 3 3 2 5 5 to a PC Laptop Start the software Close the window Konfiguration...

Page 8: ...P User Manual www anybus com Please pay attention to sufficient size of the output area TB LEN1 ADR LEN2 O1 Toggle Byte Number of following bytes from ADR to CHK Device address Number of following byt...

Page 9: ...00 signed INT 32768 32767 6 101 signed LONG 2147483648 2147483647 11 110 ASCII representation 40 111 reserved at value representation right aligned display at ASCII representation left aligned display...

Page 10: ...ard 55H fixed value or LOW byte of the sum of bytes ADR Dn Controlling devices with multiple display areas e g 2 lines The partition from O2 Dn is used repeatedly according to the number of display ar...

Page 11: ...nding on display type TB LEN1 ADR LEN2 I1 CHK Toggle byte Length Device address Length Digital Inputs Checksum 00H FFH 04H 01H 02H Bit 7 Event digital input 4 Bit 6 Event digital input 3 Bit 5 Event d...

Page 12: ...Gewerbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 4 Appendix 4 1 Displayable Characters The data bytes are ASCII coded Lower Higher 0 1 2 3 4...

Page 13: ...ply power steady green device operational flashing green No Ethernet IP configuration flashing red recoverable fault steady red internal error flashing green red self test LED 2 Network Status State D...

Page 14: ...n frame is received or transmitted LED 5 Subnet Status RS485 State Description steady off power off flashing green initializing and not running steady green running steady red stopped error or timeout...

Page 15: ...ithout response frame with response frame 4 Protocol Classic Protokoll Universal DIP2 is ignored 8 bits fixed 5 fixed value 55H instead of checksum only with protocol Universal use checksum only with...

Page 16: ...available Direct exposure to light sources or direct sun rays reduces the reading quality Turn the device off for cleaning Protect the device from excessive moisture strong vibrations direct sun expo...

Page 17: ...irm that the above men tioned product meets the requirements of the following standard Die bereinstimmung des bezeichneten Produk tes mit den Vorschriften der angewandten Richt linie n wird nachgewies...

Page 18: ...visible defects have to be indicated immediately after their perception too Generally defects and their symptoms must be described as accurately as possible in order to allow for reproducibility and e...

Page 19: ...croSYST Systemelectronic GmbH Am Gewerbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 4 7 Versions Overview Version Date Remarks Description 1 00...

Reviews: