Procedure with BCD parallel:
Switch data signals to the display digits (HIGH-active).
Set preset input (HIGH-active).
The LE input must not be operated because it is automatically supplied with a LOW
signal if it’s not connected. In this case it is active.
Procedure with BCD multiplex:
Set an HIGH-signal to the display digits you want to use.
Set data signals for digit 10
0
.
Activate LE 10
0
(= interrupt HIGH-signal or connect LOW-signal).
Repeat the last two steps for all display digits:
A...D
LE 10
0
2 ms
LE 10
1
LE 10
2
LE 10
3
LE 10
4
LE 10
5
10
0
10
1
10
2
10
3
10
4
10
5
t
Set preset input (HIGH-active).