microSYST migan MPB IZ User Manual Download Page 1

 

migan/migra MPB IZ 

 

Large Format LED Display with Pulse Counter

 

 

 

 

microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach 

 +49 9681 91960-0, 

 +49 9681 91960-10, [email protected], www.microsyst.de 

 

 

 

 

 
 

 

 

User’s Manual 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for migan MPB IZ

Page 1: ...ra MPB IZ Large Format LED Display with Pulse Counter microSYST Systemelectronic GmbH Am Gewerbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de User s Manual ...

Page 2: ...ts 1 GENERAL 3 2 SYSTEM OVERVIEW 4 3 TECHNICAL DATA 5 3 1 Tips for the Start up 6 3 2 Description of the Signals 7 3 3 Pulse Diagrams 8 3 3 1 Pulse Input 8 3 3 2 Incremental Input 9 3 3 3 Control Inputs 10 3 4 Device Configuration migan 11 3 5 Device Configuration migra 12 4 CONNECTOR PIN ASSIGNMENTS 13 5 APPENDIX 18 5 1 Declaration of Conformity 18 5 2 Maintenance and Care 19 5 3 Warranty Liabili...

Page 3: ...counting direction pulse counter or input for incremental position encoder 2 phase delayed signals Reset and preset input The configuration of the counter happens with the help of a PC software communication with the PC via USB interface With the help of BCD coded inputs settings like the preset value of the counter or overflow and underflow values can be changed within running op eration It is po...

Page 4: ...Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de Page 4 2 System Overview migan migra IZ Pulse input Incremental input Reset Preset Counting input counting direction Reset inputs for outputs optional 2 relay outputs optional BCD preselection inputs optional Voltage outputs optional ...

Page 5: ...gan controller Cut off frequencies can be configured with MKS software 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz max 2 MHz Input level adjustable with MKS software pulse input 5 V 10 V 12 V 15 V 24 V 36 V Pull up to 5 V Input level adjustable with MKS software Reset preset 5 V 10 V 12 V 15 V 24 V 36 V Pull up to 5 V Input level Ulow 0 VDC incremental input Uhigh 5 VDC Display options counting value ...

Page 6: ...t de Page 6 3 1 Tips for the Start up When putting on the power supply the following sequence has to be ob served o Connect the power supply cable to the display o Connect the power supply cable to the power supply When disconnecting the power supply the following sequence has to be observed o Disconnect the power supply cable from the power supply o Disconnect the power supply cable from the disp...

Page 7: ... input Status HIGH upwards status LOW downwards Incremental Input Differential inputs 5 V level for two phase delayed signals The upwards or downwards counting happens according to the phase shift of the both signals IDx phase a and phase B can be inverted with MKS software Reset Preset The reset preset input can be configured with MKS software for edge detection or status of input The counter is ...

Page 8: ...Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de Page 8 3 3 Pulse Diagrams 3 3 1 Pulse Input Signal level and signal frequency Counting behaviour The direction switching could possibly be executed a few milliseconds after changing the level Uhigh 5 36 VDC Ulow 0 VDC f 0 Hz to 2 MHz ...

Page 9: ... At the incremental inputp the counting direction depends on the phase shift of the two signals The maximum frequency of a single input is 1 MHz If pulse channel A hurries ahead the channel B by 90 degrees like in the picture above an UP counting happens If channel B hurries ahead the channel A by 90 degrees a DOWN counting happens This can be inverted with MKS software Pulse input A Pulse input B...

Page 10: ...GmbH Am Gewerbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de Page 10 3 3 3 Control Inputs Reset Preset Input The pulse duration ti is adjustable from 0 to 255 ms Pulse duration 10 if value is 0 ti pulse duration Uhigh 5 36 VDC Ulow 0 VDC ...

Page 11: ...0 mm Display colour red green yellow white blue Number of lines ________ Number of digits per line ________ Dimensional display _________________ View single sided double sided ____ sided Operating voltage 230 V 50 Hz 110 V 60 Hz 24 V DC Protection IP54 IP65 Operating temperature with type for inside use with type for outside use special version 0 50 C standard 20 50 C standard ___________ C 25 50...

Page 12: ...Pixel resolution horizontal x vertical ________x________ Display colour red green yellow white blue View single sided double sided ____ sided Operating voltage 230 V 50 Hz 110 V 60 Hz 24 VDC Protection IP54 IP65 Operating temperature with type for inside use with type for outside use special version 0 50 C standard 20 50 C standard ___________ C 25 50 C optional with heating Housing dimension ____...

Page 13: ...960 0 49 9681 91960 10 info microsyst de www microsyst de Page 13 4 Connector Pin Assignments The power supply happens with the 3 pin circular connector 24 VDC Optionally it s possible to supply with the 7 Pole mains plug 230 VAC Power Connector 24 VDC Power Connector 230 VAC optional Pin Assignment 1 GND 2 24 VDC 3 PE Pin Assignment 1 L1 2 N PE PE ...

Page 14: ...rd inputs 38 kΩ Incremental inputs 5 kΩ Pin Assignment 1 A incremental input 5 V 2 B incremental input 5 V 3 Output 15 VDC 4 A incremental input 5 V 5 Pulse input 1 5 36 V resp B incremental input 5 V 6 Pulse input 2 5 36 V Resp B incremental input 5 V 7 GND 8 n c 9 Reset input 5 36 V 1 0 V 0 optional at version with incremental inputs this pin is used for the signal B This pin is only optionally ...

Page 15: ...Relay 1 make resp break contact 4 Relay 1 common contact 5 Relay 2 make resp break contact 6 Relay 2 common contact 7 Relay 1 reset input 24 V 1 0 V 0 8 Relay 2 reset input 24 V 1 0 V 0 9 n c n c not connected potential free outputs depending on mounting variation make or break contact maximum switching voltage current 24 VDC 1 A This pin is only optionally connected Depending on the display s ver...

Page 16: ...nputs 15 or 24 VDC 2 Output for preselection inputs 15 or 24 VDC 3 Data 20 103 3 LE 105 4 Data 21 103 4 5 Data 22 103 5 6 Data 23 103 6 LE 104 7 7 8 Data 20 102 8 9 Data 21 102 9 LE 103 10 Data 22 102 10 11 Data 23 102 11 12 12 LE 102 13 Data 20 101 13 14 Data 21 101 14 15 Data 22 101 15 LE 101 16 Data 23 101 16 17 17 18 Data 20 100 18 LE 100 19 Data 21 100 19 20 Data 22 100 20 21 Data 23 100 21 D...

Page 17: ...Set preset input HIGH active The LE input must not be operated because it is automatically supplied with a LOW signal if it s not connected In this case it is active Procedure with BCD multiplex Set an HIGH signal to the display digits you want to use Set data signals for digit 100 Activate LE 100 interrupt HIGH signal or connect LOW signal Repeat the last two steps for all display digits A D LE 1...

Page 18: ...irm that the above men tioned product meets the requirements of the following standard Die Übereinstimmung des bezeichneten Produk tes mit den Vorschriften der angewandten Richt linie n wird nachgewiesen durch die Einhaltung folgender Normen Vorschriften The conformity of the product described above with the provisions of the applied Directive s is demon strated by compliance with the following st...

Page 19: ...ght light sources and or direct sunlight The display must be switched off before cleaning Protect the display from excessive humidity extreme vibration di rect sunlight and extreme temperatures Non observance may lead to malfunctioning or destruction of the device Under certain cir cumstances electrical shock fire and explosion may occur as well Information concerning allowable ambient conditions ...

Page 20: ...e defects have to be indicated immediately after their perception too Generally defects and their symptoms must be described as accurately as possible in order to allow for reproducibility and elimination The buy er must provide for access to the relevant device and all required and or useful information at no charge and must make all of the required data and machine time available free of charge ...

Page 21: ...5 01 13 21 03 13 17 10 13 27 04 16 16 11 16 13 11 17 Gold S Document created Gold S Default voltage for voltage outputs changed Kreuzer Housing dimensions changed Kreuzer Complete revised Kreuzer Second counting input instead of counting direction is possible Kreuzer Optionally 5 Hz impulse input Kreuzer Max output current limited to 0 5 A Kreuzer Impedances of the inputs Technical Data updated mi...