6.1. Test 

Voltages 

 

 RX 

Green 

TX 

Yellow 

Idle 6 

Handset up 

Speech 1 6 
Door release 

Handset down 

 

 

 

 

6.2. Operation 

TX  line 

  

 

1.   TX audio. 

  

 

2.   Detects when the door release button is being pressed. 

 

RX line 

  

 

1.   RX audio. 

 

CALL 

  

 

1.   14v to call handsets. 

 

GND 
1.

 

Ground to all handsets. 

7. Wiring

 

Basic layout ( one door station ) 

8. Guarantee 

The MFA02/08/20 is guaranteed by the manufacture for a period of six months from the date of 
delivery against faulty components and faulty workmanship (ex factory). 