background image

Technical data

blind zone

operating range

maximum range

angle of beam spread

20 mm
150 mm
250 mm
See detection zone

transducer frequency

resolution, sampling rate

reproducibility

detection zones

for different objects:

The dark grey areas are determined 

with a thin round bar (10 mm dia.) 

and indicate the typical operating range 

of a sensor. In order to obtain the light grey 

areas, a plate (100 x 100 mm) is introduced 

into the beam spread from the side. 

In doing so, the optimum angle between 

plate and sensor is always employed. 

This therefore indicates the maximum 

detection zone of the sensor. 

It is not possible to evaluate ultrasonic 

reflections outside this area. 

380 kHz
0.10 mm
± 0.15 %

accuracy

operating voltage U

B

voltage ripple

no-load current consumption

± 1% (Temperature drift internal compensated)
10 - 30 V DC, reverse polarity protection
±10 %

< 30 mA

housing

class of protection to EN 60 529

ABS

ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
IP 67

type of connection 

controls

 indicators

4-pin M8 initiator plug
Teach-in push-button
LED green (operation)
LED yellow (state of output)

programmable

operating temperature

storage temperature

weight

IO-Link
-25°C to +70°C
-40°C to +85°C
8 g

 switching hysteresis

switching frequency

response time

time delay before availability

2 mm
25 Hz
32 ms
< 300 ms

norm conformity

order no.

switched output

EN 60947-5-2

sks-15/CF/A

Push-Pull, U

B

-3 V, -U

B

+3 V,   I

max

 = 100 mA

switchable NOC/NCC, short-circuit-proof

1

2

4

3

+U

B

-U

B

-

U

1

2

4

3

+U

B

-U

B

-

U

Push-Pull output in pnp circuit

Push-Pull output in npn circuit

F

F

sks-15...

8  cm

4 cm

0 cm

4 cm

8 cm

0 cm

4 cm

8 cm

12 cm

16 cm

20 cm

24 cm

Round bar

Plate

microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany /

 

T

 +49 231 9 151-0 / 

F

 +49 231 975151-51 / 

E

 [email protected]

W

 microsonic.de                The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

2014/30/EU

*B13589*

MV-DO-198526-660248

 If the push-button is not pressed for

10  minutes  during  the  teach-in  set-
ting, the settings made hitherto are
deleted.

 The sensor can be reset to its fac-

tory setting.

Fig.  2:  Adjustment  of  the  switching  point
when the object moves in different directions

Notes on IO-Link

 In  IO-Link  mode,  teach-in  via  the

push-button is not available.

 For further information on IO-Link,

please contact microsonic sales.

 The current IODD library and infor-

mation on commissioning with IO-
Link  are  available  on  the  Internet
at www.microsonic.de/sks.