Technical data
blind zone
operating range
maximum range
angle of beam spread
20 mm
150 mm
250 mm
See detection zone
transducer frequency
resolution, sampling rate
reproducibility
detection zones
for different objects:
The dark grey areas are determined
with a thin round bar (10 mm dia.)
and indicate the typical operating range
of a sensor. In order to obtain the light grey
areas, a plate (100 x 100 mm) is introduced
into the beam spread from the side.
In doing so, the optimum angle between
plate and sensor is always employed.
This therefore indicates the maximum
detection zone of the sensor.
It is not possible to evaluate ultrasonic
reflections outside this area.
380 kHz
0.10 mm
± 0.15 %
accuracy
operating voltage U
B
voltage ripple
no-load current consumption
± 1% (Temperature drift internal compensated)
10 - 30 V DC, reverse polarity protection
±10 %
< 30 mA
housing
class of protection to EN 60 529
ABS
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
IP 67
type of connection
controls
indicators
4-pin M8 initiator plug
Teach-in push-button
LED green (operation)
LED yellow (state of output)
programmable
operating temperature
storage temperature
weight
IO-Link
-25°C to +70°C
-40°C to +85°C
8 g
switching hysteresis
switching frequency
response time
time delay before availability
2 mm
25 Hz
32 ms
< 300 ms
norm conformity
order no.
switched output
EN 60947-5-2
sks-15/CF/A
Push-Pull, U
B
-3 V, -U
B
+3 V, I
max
= 100 mA
switchable NOC/NCC, short-circuit-proof
1
2
4
3
+U
B
-U
B
-
U
1
2
4
3
+U
B
-U
B
-
U
Push-Pull output in pnp circuit
Push-Pull output in npn circuit
F
F
sks-15...
8 cm
4 cm
0 cm
4 cm
8 cm
0 cm
4 cm
8 cm
12 cm
16 cm
20 cm
24 cm
Round bar
Plate
microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany /
T
+49 231 9 151-0 /
F
+49 231 975151-51 /
E
W
microsonic.de The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.
2014/30/EU
*B13589*
MV-DO-198526-660248
■
If the push-button is not pressed for
10 minutes during the teach-in set-
ting, the settings made hitherto are
deleted.
■
The sensor can be reset to its fac-
tory setting.
Fig. 2: Adjustment of the switching point
when the object moves in different directions
Notes on IO-Link
■
In IO-Link mode, teach-in via the
push-button is not available.
■
For further information on IO-Link,
please contact microsonic sales.
■
The current IODD library and infor-
mation on commissioning with IO-
Link are available on the Internet
at www.microsonic.de/sks.