Set switched output
Further Settings
Sensor adjustment with Teach-in procedure
Adjust detect
point D1-
method A
Place object at
position 1.
Press T1 for about
3 s until both LEDs
flash simultaneously.
Both
LEDs:
flash
mutually
Press T1 for about
1 s.
Adjust detect
point + 8 % D1 -
method B
Place object at
position 1.
Press T1 for about
3 s until both LEDs
flash simultaneously.
Both
LEDs:
Press T1 for about
3 s until both LEDs
flash mutually again.
flash
mutually
Adjust window
mode D1
Place object at
position 1.
Adjust two-way
reflective barrier D1
Place reflector at
position 1.
Set NOC/NCC D1
Press T1 for about
3 s until both LEDs
flash simultaneously.
Press T1 for about
3 s until both LEDs
flash simultaneously.
Both
LEDs:
Place object at
position 2.
flash
mutually
Both
LEDs:
Press T1 for about
1 s.
flash
mutually
Both
LEDs:
Press T1 for about
10 s until both LEDs
stop flashing.
Press T1 for about
13 s until both LEDs
flash mutually.
flash
mutually
LED D2:
LED D1:
flashes
on: NOC/
off: NCC
To change output
characteristic press T1
for about 1 s.
Adjust detect
point D2 -
method A
Place object at
position 1.
Adjust detect
point + 8 % D2-
method B
Place object at
position 1.
Press T2 for about
3 s until both LEDs
flash simultaneously.
Both
LEDs:
flash
mutually
Press T2 for about
1 s.
Press T2 for about
3 s until both LEDs
flash simultaneously.
Both
LEDs:
Press T2 for about
3 s until both LEDs
flash mutually again.
flash
mutually
Adjust window
mode D2
Place object at
position 1.
Adjust two-way
reflective barrier D2
Place reflector at
position 1.
Set NOC/NCC D2
Press T2 for about
3 s until both LEDs
flash simultaneously.
Press T2 for about
3 s until both LEDs
flash simultaneously.
Both
LEDs:
Place object at positi-
on 2.
flash
mutually
Both
LEDs:
Press T2 for about
1 s.
flash
mutually
Both
LEDs:
Press T2 for about
10 s until both LEDs
stop flashing.
Press T2 for about
13 s until both LEDs
flash mutually.
flash
mutually
LED D1:
LED D2:
flashes
on: NOC/
off: NCC
To change output
characteristic press T2
for about 1 s.
Normal mode operation
Wait for 10 s.
Normal mode operation
Wait for 10 s.
Activate/deactivate
Teach-in
Turn supply voltage
OFF.
Reset to factory
setting
Turn supply voltage
OFF.
While pressing T1
turn supply voltage
ON.
Press T1 for about
3 s until both LEDs
flash simultaneously.
LED D2:
LED D1:
flashes
on: Teach-in
activated
off: Teach-in
deactivated
To activate or deacti-
vate Teach-in press T1
for about 1 s.
While pressing T1
turn supply voltage
ON.
Press T1 for about
13 s until both LEDs
flash mutually.
Wait for 10 s.
Normal mode operation
Operating manual
Ultrasonic proximity switch with
two switched outputs
lcs+340/DD
lcs+600/DD
Product description
The lcs+ sensor offers a non-contact
measurement of the distance to an
object which must be positioned within
the sensor’s detection zone. The swit-
ched outputs are set conditional upon
the adjusted detect distances.
Via the Teach-in procedure, the detect
distances and operating modes can
be adjusted. Two LEDs indicate opera-
tion and the state of the switched
outputs.
Optionally all Teach-in and additional
sensor parameter settings can be
made using the LinkControl Adapter
LCA-2 (optional accessory) and the
LinkControl software for windows.
Safety instructions
Read the operating instructions
prior to start-up.
Connection, installation and ad-
justments may only be carried out
by qualified staff.
No safety component in accordance
with the EU Machine Directive.
Use for intended purpose only
lcs+ultrasonic sensors are used for
non-contact detection of objects.
Installation
Mount the sensor at the place of
fitting.
Connect a connection cable to the
M12 device plug.
Start-up
Connect the power supply.
Carry out sensor adjustment in
accordance with the diagram.
Fig. 1: Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cables
Factory setting
Switched output on NOC.
Detect distance at operating range
and half operating range.
1
3
colour
+U
B
-U
B
brown
blue
4
2
5
D2
D1
black
white
Sync/Com
grey
1
5
2
3
4
Synchronisation
If under multiple sensor operation
the assembly distance falls below the
values shown in Fig. 2, the internal
synchronisation should be used. For
this purpose interconnect each pin 5
of max. 10 sensors.
Fig. 2: Assembly distances
Maintenance
microsonic sensors are maintenance-
free. In case of excess caked-on dirt
we recommend cleaning the white
sensor surface
≥
2.00 m
≥
4.00 m
≥
18.00 m
≥
30.00 m
Notes
The sensors of the lcs+ family have
a blind zone, within which a dis-
tance measurement is not possi-
ble.
The lcs+ sensors are equipped
with an internal temperature com-
pensation. Due to the sensor's self
heating, the temperature compen-
sation reaches its optimum work-
ing-point after approx. 30 minutes
of operation.
During normal operation a yellow
LED signals that the corresponding
output has connected.
If no push-buttons are pressed for
20 seconds during parameter set-
ting mode the made changes are
stored and the sensor returns to
normal mode operation.
Set switched output D1
Further settings
Set switched output D2