Set switched output

Further Settings

Sensor adjustment with Teach-in procedure

Adjust detect

point D1- 

method A

Place object at 

position 1.

Press T1 for about 

3 s until both LEDs

flash simultaneously.

Both

 LEDs:

flash 
mutually

Press T1 for about 

1 s.

Adjust detect  

point + 8 % D1 - 

method B

Place object at 

position 1.

Press T1 for about 

3 s until both LEDs

flash simultaneously.

Both

LEDs:

Press T1 for about 

3 s until both LEDs

flash mutually again.

flash 
mutually

Adjust window

mode D1

Place object at 

position 1.

Adjust two-way 

reflective barrier D1

Place reflector at 

position 1.

Set NOC/NCC D1

Press T1 for about 

3 s until both LEDs

flash simultaneously.

Press T1 for about 

3 s until both LEDs

flash simultaneously.

Both

LEDs:

Place object at 

position 2.

flash 
mutually

Both

LEDs:

Press T1 for about 

1 s.

flash 
mutually

Both

LEDs:

Press T1 for about 

10 s until both LEDs

stop flashing.

Press T1 for about 

13 s until both LEDs

flash mutually.

flash 
mutually

LED D2:

LED D1:

flashes

on: NOC/

off: NCC

To change output

characteristic press T1

for about 1 s.

Adjust detect

point D2 - 

method A

Place object at 

position 1.

Adjust detect  

point + 8 % D2- 

method B

Place object at 

position 1.

Press T2 for about 

3 s until both LEDs

flash simultaneously.

Both

LEDs:

flash 
mutually

Press T2 for about 

1 s.

Press T2 for about 

3 s until both LEDs

flash simultaneously.

Both

LEDs:

Press T2 for about 

3 s until both LEDs

flash mutually again.

flash 
mutually

Adjust window

mode D2

Place object at 

position 1.

Adjust two-way 

reflective barrier D2

Place reflector at 

position 1.

Set NOC/NCC D2

Press T2 for about 

3 s until both LEDs

flash simultaneously.

Press T2 for about 

3 s until both LEDs

flash simultaneously.

Both

LEDs:

Place object at positi-

on 2.

flash 
mutually

Both

LEDs:

Press T2 for about 

1 s.

flash 
mutually

Both

LEDs:

Press T2 for about 

10 s until both LEDs

stop flashing.

Press T2 for about 

13 s until both LEDs

flash mutually.

flash 
mutually

LED D1:

LED D2:

flashes

on: NOC/

off: NCC

To change output

characteristic press T2

for about 1 s.

Normal mode operation

Wait for 10 s.

Normal mode operation

Wait for 10 s.

Activate/deactivate

Teach-in

Turn supply voltage

OFF.

Reset to factory 

setting

Turn supply voltage

OFF.

While pressing T1

turn supply voltage

ON.

Press T1 for about 

3 s until both LEDs 

flash simultaneously.

LED D2:

LED D1:

flashes

on: Teach-in
activated
off: Teach-in
deactivated

To activate or deacti-

vate Teach-in press T1

for about 1 s.

While pressing T1

turn supply voltage

ON.

Press T1 for about 

13 s until both LEDs 

flash mutually.

Wait for 10 s.

Normal mode operation

Operating manual

Ultrasonic proximity switch with
two switched outputs

lcs+340/DD
lcs+600/DD

Product description

The lcs+ sensor offers a non-contact
measurement of the distance to an
object which must be positioned within
the sensor’s detection zone. The swit-
ched outputs are set conditional upon
the adjusted detect distances.
Via the Teach-in procedure, the detect
distances and operating modes can
be adjusted. Two LEDs indicate opera-
tion and the state of the switched
outputs.
Optionally all Teach-in and additional
sensor parameter settings can be
made using the LinkControl Adapter
LCA-2 (optional accessory) and the
LinkControl software for windows.

Safety instructions

Read the operating instructions
prior to start-up.

Connection, installation and ad-
justments may only be carried out
by qualified staff.

No safety component in accordance
with the EU Machine Directive.

Use for intended purpose only

lcs+ultrasonic sensors are used for
non-contact detection of objects.

Installation

Mount the sensor at the place of
fitting.

Connect a connection cable to the
M12 device plug.

Start-up

Connect the power supply.

Carry out sensor adjustment in
accordance with the diagram.

  
Fig. 1: Pin assignment with view onto sensor

plug and colour coding of the
microsonic connection cables

Factory setting

Switched output on NOC.

Detect distance at operating range
and half operating range.

1

3

colour

+U

B

-U

B

brown

blue

4

2

5

D2

D1

black

white

Sync/Com

grey

1

5

2

3

4

Synchronisation

If under multiple sensor operation
the assembly distance falls below the
values shown in Fig. 2, the internal
synchronisation should be used. For
this purpose interconnect each pin 5
of max. 10 sensors.

Fig. 2:  Assembly distances

Maintenance

microsonic sensors are maintenance-
free. In case of excess caked-on dirt
we recommend cleaning the white
sensor surface

 2.00 m

 4.00 m

 18.00 m

 30.00 m

Notes

The sensors of the lcs+ family have
a blind zone, within which a dis-
tance measurement is not possi-
ble.

The lcs+ sensors are equipped
with an internal temperature com-
pensation. Due to the sensor's self
heating, the temperature compen-
sation reaches its optimum work-
ing-point after approx. 30 minutes
of operation.

During normal operation a yellow
LED signals that the corresponding
output has connected.

If no push-buttons are pressed for
20 seconds during parameter set-
ting mode the made changes are
stored and the sensor returns to
normal mode operation.

Set switched output D1

Further settings

Set switched output D2