...or with the Teach-in procedure
Adjust detect point D1
Place object at position
Press T1 until »d« is shown
Current measu-
ring value
Press T1 until »End« is
shown
Adjust window mode D1
Place object at position
Press T1 until »d« is shown
Place object at position
Current measu-
ring value
Press T1 until »End« is
shown
Current measu-
ring value
Adjust two-way reflective
barrier D1
Place object at position
Set NOC/NCC D1
Adjust detect point D2
Place object at position
Press T1 until »d« is shown
Current measu-
ring value
Press T1 until countdown
passed from »- 8 -« to »- 0 -«
and NOC or NCC symbol is
displayed
Press T1 until countdown
passed from »- 8 -« to »- 0 -«
and »End« is displayed
To change output function
press T1
Press T1 and T2 simultaneous-
ly until »End« is displayed
Symbol
NOC or NCC
Press T2 until »d2« is shown
Current measu-
ring value
Symbol
NOC or NCC
Press T2 until »End« is
shown
Adjust window mode D2
Place object at position
Adjust two-way reflectiv
barrier D2
Place reflector at position
Set NOC/NCC D2
Press T2 until »d2« is shown
Place object at position
Current measu-
ring value
Press T2 until »End« is
shown
Current measu-
ring value
Press T2 until »d2« is shown
Current measu-
ring value
Press T2 until countdown
passed from »- 8 -« to »- 0 -«
and NOC or NCC symbol is
displayed
Press T2 until countdown
passed from »- 8 -« to »- 0 -«
and »End« is displayed
To change output function
press T2
Press T1 and T2 simultaneous-
ly until »End« is displayed
Symbol
NOC or NCC
Symbol
NOC or NCC
Normal mode operation
Normal mode operation
T1 + T2
T1
T2
T1 + T2
Press T1 and T2 simultaneously for about 13 s
until »Add« is shown in the LED-display
T1 + T2
T2
T1
Start here
T2
T1
T1 + T2
Ready
»C01«: Display
bright
»C02«: Display dim-
med
»C03«: Display off
To optimize multi-
plex speed the hig-
hest sensor address
may be set.
Setting range »01«
to »10«
»F00«: no filter
»F01«: standard fil-
ter
»F02«: averaging fil-
ter
»F03«: foreground
filter
»F04«: background
filter
Defines the strength
of the chosen filter.
»P00«: weak filter
up to
»P09«: strong filter
Affects the size of
the detection zone.
»E01«: high
»E02«: standard
»E03«: slight
Minimum value:
blind zone
Maximum value: ne-
arwindow limit - 1
Low power mode
Measurement filter
Filter strength
Foreground
suppression
Multiplex mode
device addressing
Multiplex mode
highest address
»00«: synchronisati-
on
»01« to »10«: sensor
address for multi-
plex mode
»oFF«: synchronisati-
on deactivated
Minimum value: sen-
sor-distant window
margin
Maximum value:
999 mm for
hps+25/...,hps+35/...,
999 cm for
hps+130/...,hps+340/
Measurement range
Calibration
display
Detection zone
sensitivity
Put plane reflector
vertically disposed in
front of sensor: in
an exact distance of
250 mm for hps+
25... and hps+35...
and 900 mm for all
other typs.
Adjust display to
250 mm or 900 mm.
Confirm calibration
with T1 + T2.
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
Delay in seconds
between the detec-
tion of an object
and the output of
the measured dis-
tance in case of ob-
ject approach (beha-
ves as on-delay).
"00": 0 s (no delay)
up to
"20": 20 s response
time
Response time
T1 + T2
T1
T2
T1 + T2
T2
T1
Note
Changes in the Add-on
menu may impair the
sensor function.
A6, A7, A8 , A10 , A11,
A12 have influence on
the response time of
the sensor.
Hysteresis
switched output D2
Minimum value:
»001«
Maximum value: dif-
ference between
maximum range and
detect point - 1
During window
mode operation hys-
teresis influences
both detect points.
T1 + T2
T1
T2
T1 + T2
T2
T1
Hysteresis
switched output D1
Minimum value:
»001«
Maximum value: dif-
ference between
maximum range and
detect point - 1
During window
mode operation hys-
teresis influences
both detect points.
T1 + T2
T1
T2
T1 + T2
T2
T1
Usefull additional functions in Add-on menu (for experienced users only, settings not required for standard applications)
Teach-in switched output D1
Teach-in switched output D2
Key lock and factory setting
Activate/deactivate
TouchControl
Reset to factory set-
ting
Turn supply voltage
OFF
While pressing T1 turn
supply voltage ON
until »on« or »off« is
displayed
Turn supply voltage
OFF
Turn supply voltage
ON while pressing T1
and keep it pressed
for ca. 15 s until
»rESEt« has passed
through the display
To activate or
deactivate press T1
»on« or
»off«
To activate or
deactivate press T1
»on« or
»off«
Normal mode operation
Release T1 before
turning supply
voltage OFF