![Microsensor MPM4811 Operation Manual Download Page 7](http://html1.mh-extra.com/html/microsensor/mpm4811/mpm4811_operation-manual_1788540007.webp)
5
Method 1: Insert a steel tube in the water channel(see figure 3).
The steel tube wall should be thicker, and several holes should be
made at different heights of the tube to damp waves and clear the
water pressure influence.
Method 2: Superficial burying is better in the sand and stone
channel(see figure 4).
Method 3: If the pressure is high in the flowing water or there are
sediments in the water, please install refer to figure 5.
E l e c t n i ca l C o n n e c t io n B o x
E L e c t n i c a l C o n n e c t i o n Bo x
Figure 3 Figure 4
Figure5
Damper
Air Pocket
Summary of Contents for MPM4811
Page 1: ...MPM4811 Operation Manual...
Page 12: ......