background image

and steel needle, and it is also not allowed to press the diaphragm with hands, 

so as not to damage the diaphragm or cause the diaphragm to deform. 

3.2.2.1 Installation in still water: 

a)  The installation method in the pool is shown in Figure 2. In order to 

prevent  the  impact  of  the  pump  from  shaking  and  damaging  the 

transmitter,  the  transmitter  should  be  placed  away  from  the  liquid 

inlet and outlet. Otherwise, the steel pipe protection method shown 

in Figure 3 should be used. 

b)  The installation in the deep well is shown in Figure 3. Generally, the 

method  of  inserting  steel  pipes  is  used.  It  is  required  that  the  steel 

pipe cannot be bent, and the inner diameter must be larger than the 

outer diameter of the transmitter. Several small holes are punched at 

different  heights  of  the  steel  pipe  to  facilitate  the  smooth  entry  of 

water  into  the  pipe.  If  necessary,  wind  a  steel  wire  around  the 

transmitter  and  lift  it  up  and  down  with  the  steel  wire  to  avoid 

breaking the cable. 

 

 

 

 

 

 

Figure 2                                      Figure 3 

Summary of Contents for MPM426W Series

Page 1: ...V1 0 MPM426WSeries Operation Manual...

Page 2: ...1...

Page 3: ...iability and a special digital compensation circuit that are housed in a rugged stainless steel 316L housing It offers an integrated structure supports multiple standard outputs and cable options of m...

Page 4: ...range 200mH2O 0 35bar range 350bar 0 25 FS range 10mH2O range 1bar Compensated Temperature 10 60 Long term stability 0 2 FS year Overload 2 times full scale pressure Vibration 20g 20Hz 2000Hz Shock 2...

Page 5: ...r 2 2 Output parameters Table 2 Output Signal Output form Supply Voltage 4 mA 20mA DC E 2 wire 12V 28V DC 0 5V DC F 3 wire 15V 28V DC 1V 5V DC J 15V 28V DC 0 10V DC V 15V 28V DC 0 5V 4 5V DC K2 15V 28...

Page 6: ...safety parameters Intrinsically Safe Explosion proof Markings ATEX 2460 1G Ex ia C T4 Ga IECEx CSAE 22 0019 CSANe 22ATEX1004 CSAUS CSA22CA801063 Class Division 1 Groups A B C and D T4 Ex ia C T4 Ga Cl...

Page 7: ...Output Circuit 3 2 5V DC Power Supply 6V DC 100mA DC 1 44uH 0 318 F 0 2W Digital Output Circuit RS485 25 4 V DC 90mA DC 1 44uH 13 2 F 0 56W 3 Outline Construction and Installation 3 1 The outline dra...

Page 8: ...he measuring medium would not jam the pressure leading hole 3 2 2 Installation method Generally the transmitter should be installed perpendicular to the horizontal direction If restricted by environme...

Page 9: ...utlet Otherwise the steel pipe protection method shown in Figure 3 should be used b The installation in the deep well is shown in Figure 3 Generally the method of inserting steel pipes is used It is r...

Page 10: ...e steel pipe wall is required to be slightly thicker and a number of small holes are punched in the pipe wall at different heights to dampen water waves and eliminate the influence of hydrodynamic pre...

Page 11: ...Figure 6 4 Electrical Connection Table 4 4 1 Typical electrical connection a 2 wire Wire Color 2 wire current 3 wire voltage 4 wire RS485 Red V V V White Null OUT RS485B Black OV OUT GND GND Yellow Gr...

Page 12: ...the atmosphere During installation and use the tube must be connected to the atmosphere do not be blocked and liquids must not flow in from the tube otherwise the transmitter will be damaged 5 Unpack...

Page 13: ...tion Certificate 1pc 7 3 Storage The transmitter should be stored in dry ventilate room ambient temperature 20 85 and the relative humidity 85 no corrosive substance in the room 6 Operation maintenanc...

Page 14: ...ts the power supply should be turned off first check again whether the installation and wiring meet the requirements of the manual whether the power supply current is correct and whether the vent pipe...

Page 15: ......

Reviews: