20
Please log on iot.microsensor.cn to download the configuration software.
Figure 3.1 DB9 configuration line
3.2 Local configuration method
After the device is powered on, connect the standard USB-RS485 serial
line to the PC, and connect the DB9 configuration cable to the device,
then run the configuration software.
The product comes with a standard DB9 configuration cable. Users need
to purchase the USB-RS485 serial line (Z-TEK ZE628 is recommended)
by themselves. Please note, when the RS485 interface is used in the
Configuration Mode, Pin 6 needs to be powered with 3.3V~12VDC for
the configuration mode I/O detection, otherwise it cannot enter the
configuration mode; In the configuration software, select the
communication port to set the baud rate to 115200, no parity bit, stop bit
1 bit, and open the serial port. (The serial port is open on the screen,
indicates that it is in the configuration mode)