Status LEDs
Status LEDs
The four tricolor LEDs provide the following status information:
Red
Orange
Green
Dark
Sync
SyncServer is
not synchronized
to a
reference.
NTP Stratum 16.
SyncServer is syn-
chronized to a remote
NTP server.
NTP Stratum 2-15.
SyncServer is synchronized to
an Input Reference or the
modem
1
.
NTP Stratum 1.
Power off.
Network
Link failure on the
LAN1.
Link failure on the LAN2,
LAN3, or LANGBE.
All configured ports operational. Power off.
NTP
>7000 NTP pack-
ets per second.
> 5000 packets per
second.
NTP activity within the last
second.
No NTP
activity in
the last
second.
Alarm
Major Alarm.
Minor Alarm.
No Current/Enabled Alarms.
Power off.
Also see
Stratum
(on page 202).
Halting the SyncServer
Microsemi recommends shutting the operating system down before removing the power.
Using the keypad/display interface:
1. Press the
MENU
button.
2. Select
3) Sys Control
.
3. Select
2) Shutdown
.
4. Press the
ENTER
button.
5. When the display shows "System Stopped - OK to Turn Power Off Now!" turn the power
off.
Or, using the web interface:
1. Go to the
SERVICES - Startup
page.
2. Select
Halt
and click the
APPLY
button.
3. Wait approximately 30 seconds before removing power.
1
The SyncServer S350i does not include a modem.
997-01520-02 Rev. F1
..........................................................................
Page 15