© Microsemi Corp.
Microsemi
Page 13
Rev.B01 CPG
– Poe BU
One Enterprise Aliso Viejo, CA 92656 USA
Table
3-2: Port Status Indications PD-96xx Series
Port LED
Color
Port Load
Conditions
Port Voltage
Off
Inactive load or
unplugged port
Power to port is
disconnected. No DC voltage
present on port output lines.
Green
Active load is
plugged in and
complies with normal
load conditions.
Continuous nominal DC voltage
is present
according to 4-Pairs
configuration
.
Yellow
Active load is
plugged in and
complies with normal
load conditions.
Continuous nominal DC
voltage is present on 2-wire
pairs.
Green blinks
once every
second
Overload or short
circuit
Power to port is
disconnected.
No DC voltage is present on
port output lines.
Green blinks
once every
0.5 seconds
Valid load.
Total aggregated
power exceeds
predefined power
budget
Power is not connected to
port.
No DC voltage is present on port
output lines
3.3
Connectors
On Midspan’s front panel there’s a Console port. Using a standard USB
cable, users can connect a terminal to this port and load software.
Note
: USB connection requires 'CP210x Driver.exe' installation.
Supplied CD provides the driver.
Console port is set to 38,400-baud for managed units and 19,200-baud
for unmanaged units, 8 data bits, no parity, and 1 stop bit. Figure
displays pin connections for this connector.