F
Technical Specifications
F.1
Environmental Specifications
Note: Microsemi Adaptec RAID controllers require adequate airflow to operate reliably.
The recommended airflow is 200 LFM (linear feet per minute), minimum. Forced airflow
is required.
0 °C to 55 °C
Ambient temperature with forced airflow
0 °C to 55 °C
Ambient temperature with Flash Backup Unit
10% to 90%, non-condensing
Relative humidity
Up to 3,000 meters
Altitude
Note: Ambient temperature is measured 1 inch from the RAID controller processor.
F.2
DC Power Requirements
Requirements
Description
Bus Type
50 mV peak-to-peak (max.)
Ripple and noise
PCIe
3.3 V ± 9%, 12 V ± 8%
DC voltage
PCIe
F.3
Current Requirements
Typical Current
Controller Model
0.1 A at 3.3 VDC; 1.2 A at 12.0 VDC
Microsemi Adaptec RAID 8405/8405E
0.1 A at 3.3 VDC; 1.2 A at 12.0 VDC
Microsemi Adaptec RAID 8805/8805E
0.1 A at 3.3 VDC; 1.2 A at 12.0 VDC
Microsemi Adaptec RAID 8885/8885Q
1.0 A at 3.3 VDC; 1.1 A at 12.0 VDC
Microsemi Adaptec RAID 81605Z/81605ZQ
F.4
Supercapacitor Ratings
Microsemi Adaptec Flash Backup Module AFM-700
Specification
5.4 V
Maximum voltage
2.5 V
Minimum voltage
0.5 A
Maximum rated charge current
0.5 A
Maximum rated discharge current
76
Microsemi Proprietary and Confidential. Installation and User's Guide Revision 5
Technical Specifications