background image

Safety Information 

 

Important Safety Information 

 

Installation and removal of the PoE Midspan must be 

carried out by qualified personnel only.  

  AC Power Cord Set: 

o

 

The power cord must have regulatory agency 
approval for the specific country in which it is being 
used (i.e., UL, CSA, VDE, etc.).  

o

 

The power cord must be a three-conductor type 
(two current carrying conductors; one ground 
conductor) terminated on one end by an IEC 60320 
appliance coupler (for connection to the PoE 
Midspan), and on the other end by a plug containing 
a ground (earthing) contact.  

o

 

The power cord must be rated for a minimum of 
250Vac RMS operation, with a minimum rated 
current capacity of 5 Amps  (or a minimum wire 
gauge of 18 AWG (0.75mm2).  

 

:  PoE  Midspans  installed in Australia require power 

cords with a minimum wire gauge of 16 AWG (1.0 mm

2

).   

: The PoE injector "Data In" and "Data & Power Out" 

ports are shielded RJ45 data sockets. They cannot be used as 
Plain Old Telephone Service (POTS) telephone sockets. Only 
RJ45 data connectors may be connected to these sockets.  

o

 

The AC wall socket-outlet must be near the PoE 
Midspan and easily accessible. You can remove AC 
power from the PoE  Midspan by disconnecting the 
AC power cord from either the wall socket-outlet or 
the PoE Midspan appliance coupler.  

o

 

The  PoE  Midspan  Data In and  Data & Power Out 
interfaces are qualified as SELV (Safety Extra-Low 
Voltage) circuits according to IEC 60950-1. These 
interfaces can only be  connected to SELV 
interfaces on other equipment. 

WARNINGS!   

 

Read the installation instructions before connecting the 

PoE Midspan to its power source. 

 

Follow basic electricity safety measures whenever 

connecting the PoE Midspan to its power source. 

 

A voltage mismatch can cause equipment damage and 

may pose a fire hazard. If the voltage indicated on the 
label is different from the power outlet voltage, do not 
connect the PoE Midspan to this power outlet. 

 

The equipment is intended only for installation in a 

Restricted Access Location/ 

Mounting Instructions 

Perform the following: 
1.  Install two screws in the wall or shelf as shown below: 

 

Figure 1: Mounting Instructions

 

2.  Align the unit's mounting slots to capture the surface screws 
3.  Connect the ground studs as shown below: 

Stud diameter =  5 mm

Connect this side

To earth ground

Stud diameter =  5 mm

 

Figure 2: Stud Connection to Ground

 

 

 

Recycling and Disposal 

Disposal instructions for old products. The WEEE (Waste Electrical 
and Electronic Equipment) national environmental initiatives has 
been put in place to ensure that products are recycled using best 
available treatment, recovery and recycling techniques to ensure 
human health and high environmental protection. Your product is 
designed and manufactured with high quality materials and 
components, which can be recycled and reused. Do not dispose of 
your old product in your general household waste bin. Inform 
yourself about the local separate collection system for electrical and 
electronic products marked by this symbol:  

Use one of the following disposal options : 
1.  Dispose of the complete product (including its cables, plugs 
and accessories) in the designated WEEE collection facilities. 
2.  If you purchase a replacement product, hand your complete 
old product back to the retailer. He should accept it as required 
by the national WEEE legislation.

 

 
Ordering information:  

  Product Name:

 Microsemi 9001G-40/SP 

  Part Number:

 PD-9001G-40/SP/AC  

  Description:

 1-Port 802.3at 40W Gigabit PoE Midspan with 

Surge Protection 

 

  Document P/N 06-0062-056 Rev. C00 

 

 

 

 

 

 

 

 

M

M

i

i

c

c

r

r

o

o

s

s

e

e

m

m

i

i

 

 

9

9

0

0

0

0

1

1

G

G

-

-

4

4

0

0

/

/

S

S

P

P

 

 

U

U

s

s

e

e

r

r

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

1

1

-

-

P

P

o

o

r

r

t

t

 

 

8

8

0

0

2

2

.

.

3

3

a

a

t

t

 

 

4

4

0

0

W

W

 

 

G

G

i

i

g

g

a

a

b

b

i

i

t

t

 

 

P

P

o

o

E

E

 

 

M

M

i

i

d

d

s

s

p

p

a

a

n

n

 

 

w

w

i

i

t

t

h

h

 

 

S

S

u

u

r

r

g

g

e

e

 

 

P

P

r

r

o

o

t

t

e

e

c

c

t

t

i

i

o

o

n

n

 

 

 

 

 

 

 

Notice 
 

It is Microsemi’s policy to improve its products as new 
technology, components, software, and firmware 
become available. Microsemi, therefore, reserves the 
right to change specifications without prior notice. 
 

Technical Support 

If you encounter problems when installing or using this 
product, please consult the Microsemi website at: 
http://www.microsemi.com 

  For technical support, call: +972-9-775-5123 

  In the USA:  1-877-480-2323 

 

 

  Email: [email protected]  

 
 
 

 Microsemi Corp. 

Covered under one or more of US Patents: 
#7,006,815; and 7,437,217. 
 
 
 
 

 
 

 

 

Reviews: