Microscan QX Hawk Quick Start Manual Download Page 2

Copyright 

©

2014 Microscan Systems, Inc.

Step 8 — Calibrate

Imager settings can be adjusted automatically for optimum        

performance by either the EZ Button or by 

ESP

.

During the calibration routine, the imager will flash its Read  Rate 

percent LEDs and illumination LEDs while searching   camera   

settings and determining the best configuration for decoding symbol 

data. Upon successful completion of this    routine, a green LED 

pattern will flash brightly and illuminate  the symbol. If unsuccessful, 

the imager will emit 5 short beeps and stop searching.

Calibrate by ESP

1. Click the 

Calibrate

 button.

2. The imager will search camera settings to determine the best 

configuration for decoding symbol data.
A successful calibration will display a green frame around the 

symbol, and the following message will appear: “Uploading 

all reader parameters.” After a moment the symbol data will 

be presented in the field below the image display window.

Calibrate by EZ Button

1. Hold down the EZ Button for about two seconds and release 

when you hear 

two short beeps

. The

 20%

 and 

40%

 LEDs 

on the top of the unit will illuminate.

2. The imager will search camera settings to determine the best 

configuration for decoding symbol data.

Note:

 To end all EZ Button functions, press the EZ Button 

once and quickly release.

Calibrate by Serial Command

Send 

<@CAL>

 from a terminal program to begin auto-calibration.

Step 6 — Connect

To connect using the Connection Wizard:

• Click 

Connect

 on the menu toolbar, and then select 

Connection 

Wizard

.

• Select 

RS-232

 or 

Ethernet

 to activate the appropriate display.

• Configure settings as required by the application, and click 

Connect

.

• When a connection is established, the green indicator in the status 

bar at the bottom right of the screen will be visible:

Important:

 The imager is in 

Continuous Read Mode

 by default. 

For best connection results, be sure that no decodable symbols 

are within the imager’s field of view while attempting to connect.

Step 9 — Test Read Rate

Read Rate

 indicates the number of successful decodes per second 

achieved by the imager. 

Test Read Rate by ESP

1. Click the 

Test

 button to start the 

Read Rate

 test.

If a symbol has been successfully decoded, its data and 

related information will be presented in the field below the 

image display window. While the symbol is being decoded, 

the Read Rate LEDs will indicate the read rate percentage on the 

top of the unit.

2. Click the 

Stop

 button to end the Read Rate test.

Note:

 Read rate can also be tested using the Read Rate

 

interface 

in 

Utilities

.

Test Read Rate by EZ Button

1. To start the Read Rate test, hold down the EZ Button about 

three seconds until you hear 

three short beeps

. The 

20%

40%

, and 

60%

 LEDs on the top of the unit will illuminate.

While the symbol is being decoded, the Read Rate LEDs will 

indicate the read rate percentage on the top of the unit.

2. To end the Read Rate test, press the EZ Button and quickly 

release.

Test Read Rate by Serial Command

You can also start a test with the 

<C>

 or 

<Cp>

 command and end it 

with the 

<J>

 command.

Step 7 — Locate Symbol

Locate by ESP

• In 

ESP

’s 

EZ Mode

, click the 

Locate

 button to enable the red 

X

 pattern.

The symbol in the field of view will appear in the video view 

beneath the 

Locate

 and 

Calibrate

 buttons, and you will see the 

red target

 

pattern projected from the front of the imager.

• Center the target

 

pattern on the symbol.

Important: 

The entire symbol should fall within the field of view 

(FOV) of the imager. The field of view is what appears in 

ESP

’s 

Locate/Calibrate

 window in 

EZ Mode

.

• Click the 

Stop

 button to end the 

Locate

 function.

Locate by EZ Button

If you are not connected to a host computer, the EZ Button allows 

you to locate the symbol in the imager’s field of view.
• Hold down the EZ Button for about one second and release when 

you hear one short beep. The amber 

20%

 LED will illuminate, 

and you will see the red target

 

pattern projected from the front of 

the imager.

• Center the target

 

pattern on the symbol.

Note:

 To end all EZ Button functions, press the EZ Button once 

and quickly release.

Step 10 — Configure and Save

Click the 

App Mode

 button to make configuration changes.

The following modes are accessible by clicking the buttons at the top 

of the screen:

• Click the 

EZ Mode

 button to return to EZ Mode.

• Click the 

Autoconnect

 button to establish communication.

• Click the 

Send/Recv

 button to send or receive commands.

• Click the 

Switch Model

 button to open the model menu.

• Click the 

Parameters

 button to show the tree controls for        

Communication, Read Cycle, Symbologies, I/O Parameters,   

Symbol Quality, Matchcode, and Diagnostics.

• Click the 

Setup

 button to access the Camera Setup tree and the 

interfaces for Video, Evaluation, Calibration, Window of Interest 

(WOI), Configuration Database, Ordered Output, Output Format, and 

Dynamic Setup.

• Click the 

Terminal

 button to display decoded symbol data, and to 

send serial commands to the imager using text or macros.

• Click the 

Utilities

 button to show the tabbed interfaces for Read Rate, 

Counters, Device Control, Differences from Default, Master Database, 

and Firmware.

Saving Options

Send, No Save

. Changes will be lost when power is re-applied to 

the imager.

Send and Save

. This activates all changes in current memory 

and

 

saves to the imager for power-on.