Chapter 3
Serial Configuration
3-14
MS-850 Raster Scanner User’s Manual
3–Ser
ial
Conf
ig.
PDF417
Format: <
K[
status,raster sweeps before decode attempt,fixed length status, fixed
length
>
Example: To enable PDF417 and set raster sweeps before decode attempt to 4,
send <K[1,4>.
UPC
Format: <
Ks
UPC status,EAN status,supplementals status,separator status,separator
character
>
Example: To change Supplementals to Required, and change Separator Character to a
dash (–), send <Ks1,1,2,1,–>.
Code 128
Format: <
Kt
status,fixed code length status,code length,,,,
>
Example: To enable Code 128, enable Fixed Code Length, and set Code Length to 9,
send <Kt1,1,9>.
status:
0 = Disabled
1 = Enabled
raster sweeps before
decode attempt:
Default is
0
0 to 4
fixed length
status:
0 = Disabled
1 = Enabled
fixed length:
Default is
10
1 to 2710
UPC status:
0 = Disabled
1 = Enabled
EAN status:
0 = Disabled
1 = Enabled
(UPC must also be
enabled)
supplementals status:
0 = Disabled
1 = Enabled
2 = Required
separator status:
0
= Disabled
1 = Enabled
separator character:
Any ASCII character (except NUL). Default is a
comma
(,)
.
status:
0 = Disabled
1 = Enabled
fixed code length status:
0 = Disabled
1 = Enabled
code length:
Default is
10
.
Any number from 1 to 64.