Chapter 2
Menu Configuration
2-32
MS-850 Raster Scanner User’s Manual
2–Menu Conf
ig
.
Application Record Padding
Default:
Disabled
Options:
Disabled, Enabled
Note
: Application Record must be enabled under Format before this parameter can
take effect.
Padding is the insertion of zeros to make up the maximum length of a variable appli-
cation identifier field, except for the last field which does not require padding.
When enabled, padding is included. When disabled, padding is omitted.
Note
: Padding is never added to fixed length fields or to the last data field of a label.
Enabling or disabling padding will have no effect on these.
AIAG
Default:
Disabled
Options: Disabled,
Enabled
AIAG has 12 Identifiers, each of which allows you to enter up to 4 ASCII characters
with the exception of ID #5 which allows you enter 3 sub-identifiers of 4 characters
each.
Code 93
Default:
Disabled
Options: Disabled,
Enabled
Fixed Code Length
Default:
Disabled
Options:
Disabled, Enabled
Allows you to increase data integrity by ensuring that only one label length will be
accepted.
Code Length
Default:
10
Options:
1 to 64
Allows you to specify the exact number of characters that the scanner will recognize
(this does not include start and stop). The scanner will ignore any code not having the
specified length.