Chapter 2
2-26
MS-810 Industrial Scanner User’s Manual
2–Menu Conf
ig
.
), an invalid check digit calculation will cause a noread
message to be transmitted at the end of the read cycle.
Check Digit Output
Default:
Disabled
Options: Disabled,
Enabled
When enabled, the check digit character is sent along with the label data. When dis-
abled, label data is sent without the check digit.
Large Intercharacter Gap
Default:
Disabled
Options:
Disabled, Enabled
Allows the scanner to read labels with gaps between bar code characters exceeding
three times the narrow element width.
Fixed Code Length
Default:
Disabled
Options:
Disabled, Enabled
Used to increase data integrity by ensuring that only one label length will be accepted.
Code Length
Default:
10
Options:
1 to 64
Note:
Fixed Code Length must be enabled for Code Length to take effect.
Allows you to specify the exact number of characters that the scanner will recognize
(this does not include start and stop). The scanner will ignore any code not having the
specified length.
Codabar
Default:
Disabled
Options: Disabled,
Enabled
Start & Stop Match
Default:
Enabled
Options:
Enabled, Disabled
Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid
read can occur.
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...