Operational Commands
MS-610 Scanner User’s Manual
4-3
4–Oper
a
ti
ons.
Program Management Commands
<A> Software Reset.
Initializes all serial
configuration commands in RAM and
resets all counters and operating param-
eters. Changes for Baud Rate, Code
Length, etc. do not take effect until this
command is sent.
Note:
Software Reset will cause the numeric counters in use to lose their count;
record all data that you wish to save prior to sending this command.
<D> Enter Configuration Mode.
Enters the menu configuration program. See
Chapter 2, “Menu Configuration.”
<Z> Software Reset/Save Parame-
ters for Power-on.
Saves the current
configuration to nonvolatile memory for
availability on power-on.
The values of numeric counters are not
saved by this command.
Note:
The <Z> Save Configuration command can be executed at least 10,000
times. In normal usage this will exceed the life of the scanner. If frequent
changes to the operating parameters are required, it is recommended that the
<Z> command be used only when the current configuration has been changed
and the changes are to be permanent.
Device Control Commands
<H> Enable Laser Scanning (Laser On).
<I> Disable Laser Scanning (Laser Off).
This feature is useful during
extended periods of time when no bar code labels are being scanned. Dis-
abling laser scanning will not affect any downloaded commands to the scanner.
<L> Host Relay Driver Pulse.
Allows you to send a pulse to pin 7 at any time
regardless of Match Code or Relay Driver status.
Initialize
<A>
RAM
NOVRAM
ROM
Initialize
RAM
NOVRAM
ROM
<Z>