Chapter 2
Menu Configuration
2-16
MS-610 Scanner User’s Manual
2–Menu Conf
ig.
Noread Message
Default:
NOREAD
Options: Up to seven ASCII characters (except NUL)
Allows you to define any combination of ASCII characters (except NUL) up
to seven characters as the noread message. When enabled, the noread
message will be transmitted to the host at a timeout or the end of a read cycle if
the bar code label has not been decoded.
Noread Message (enable/disable)
Default:
Enabled
Options: Enabled, Disabled
Note: If Noread Output is enabled, the noread message will only output if Bar
Code Output (page 2-16) is also enabled.
Allows you to enable or disable the noread message.
Bar Code Output
Default: Enabled
Options: Enabled, Disabled
Allows you to choose whether or not to send label data (or noread mes-
sages) to the host. When disabled, a label is decoded and the read cycle
transpires as usual, but neither label data nor the noread message is trans-
mitted to the host. All scanner counters are updated, and the number of
good reads or noreads can be obtained via operational commands.
When to Output (bar code data)
Default:
As Soon As Possible
Options: As Soon As Possible, End of Read Cycle
Allows you to choose when bar code data is sent to the host.
Selecting:
Has this effect:
As Soon As Possible
Causes bar code data (good reads) to be
transmitted immediately upon a good decode.
End of Read Cycle
Causes bar code data output to be delayed until the
end of the read cycle.