Serial Commands
MS-5000 Multidrop Concentrator User’s Manual
4-5
4–Oper
a
ti
ons.
LAN Port
Baud Rate, Parity, Stop Bits, Data Bits
Set communications parameters for the LAN port.
Format: 51<Kl
baud,parity,stop bits,data bits
>CR
Example:
To change Stop Bits to Two and ensure that default parameters
remain the same, enter
51<Kl,,1>CR or 51<Kl4,1,1>CR
.
To change Baud to 19.2 K, enter
51<Kl5>CR
.
RS-422
Toggle between RS-232 and RS-422.
Format: 51<
Km
status
>CR
Example:
To enable RS-422, enter
51<Km1>CR
.
Turnaround Timeout
,
Number of Devices
Time the concentrator will wait between inidvidual characters from a LAN
device.
Format: 51<
Kn
timeout, number of devices
>CR
t
Example:
To change the timeout to 30 ms and the number of devices to 10,
enter
51<Kn30,10>CR
.
baud rate:
0 = 600
4 = 9600
1 = 1200 5 = 19.2K
2 = 2400 6 = 300
3 = 4800
parity:
0 = None
1 = Even
2 = Odd
stop bits:
0 = One
1 = Two
data bits:
0 = Seven
1 = Eight
LAN RS-422 Status:
0 = Disabled
1 = Enable
LAN Turnaround Timeout:
Any number from 1 to 250.
Default is
15 ms
.
Number of Devices:
Any number from 1 to 50.
Default is
50
.
Summary of Contents for MS-5000
Page 1: ...MS 5000 Multidrop Concentrator User s Manual P N 83 005000 REV J...
Page 8: ...viii MS 5000 Multidrop Concentrator User s Manual...
Page 52: ...Chapter 3 Menu Configuration 3 18 MS 5000 Multidrop Concentrator User s Manual 3 Serial Config...
Page 66: ...Chapter 4 Serial Commands 4 14 MS 5000 Multidrop Concentrator User s Manual 4 Operations...
Page 90: ...A 14 MS 5000 Multidrop Concentrator User s Manual Appendices...