MS-1 Scan Engine
User Manual
6-15
Read Cycle
No Read Message
Note:
A
No Read
message can only be transmitted when in
Single
symbol mode and no
decodes occur.
No Read Status
No Read Message
Note:
A
No Read
message is not output when the MS-1 is disabled (when an
<I>
command
has been sent).
Usage:
Used in applications where the host needs serial verification that a symbol
has not been read.
Definition:
When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the No Read message will be transmitted to the host.
Serial Cmd:
<
K714,
status
,No Read message
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Definition:
Any combination of ASCII characters can be defined as the No Read
message.
Serial Cmd:
<
K714,
status,
No Read message
>
Default:
No Read
Options:
1 to 20 ASCII characters.