Verification Types
Da
ta Matrix
Ve
ri
fi
c
a
ti
o
n
3
v2.4.1, Nov 2008
HawkEye™ 1500 Series Verification Manual
3-17
AIM DPM-1-2006
This standard is applicable to a broad range of applications, industries and
marking methods.
TABLE 3–4.
AS9132 Rev. A, 2005 Numeric Score to Grade Level Comparison
Grade
A
4
B
3
C
2
D
1
F
0
Comments
Angle of Distortion
<3.5
<7
> 7
Cell Fill
65%-105%
P/F Only
<65%
or >105%
Ref Only – Ideal is
80%
Dot Center Offset
C1< 2%
C2<2%
C2>20%
C1 is the count of
cells having center
offset less than 10%
of nominal module
size.
C2 is the count of
cells having center
offset less than 20%
of nominal module
size.
Dot Size Offset
C1<2%
C2<2%
C2>2%
C1 is the count of
cells having size
offset errors between
70%-90% of nominal
module size.
C2 is the count of
cells having size
offset errors between
60%-105% of nominal
module size.
Nominal Module
Size
Ref Only
Ovality
C1 < 2%
C2 < 2%
C2 > 2%
C1 and C2 are count
of cells having ovality
greater than 20% of
nominal module size.
Summary of Contents for HawkEye 1500 Series
Page 1: ...HawkEye 1500 Series Verification Manual EM 40393 1V241 v2 4 1 Nov 2008...
Page 4: ......
Page 8: ...Contents viii HawkEye 1500 Series Verification Manual v2 4 1 Nov 2008...
Page 10: ...Preface x HawkEye 1500 Series Verification Manual v2 4 1 Nov 2008...
Page 16: ...Chapter 1 Why Verification 1 6 HawkEye 1500 Series Verification Manual v2 4 1 Nov 2008...
Page 58: ...Chapter 4 Barcode Verification 4 6 HawkEye 1500 Series Verification Manual v2 4 1 Nov 2008...